Fnc290 - Loadr / Load From Er - Mitsubishi FX3U Series Programming Manual

Hide thumbs Also See for FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series Programmable Controllers
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
33.1
FNC290 – LOADR / Load From ER
Outline
This instruction reads the current values of extension file registers (ER) stored in a memory cassette (flash
memory), and transfers them to extension registers (R) stored in the PLC's built-in RAM.
1. Instruction format
FNC 290
LOADR
2. Set data
Operand Type
S
n
3. Applicable devices
Bit Devices
Oper-
and
System User
Type
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
S
n
Explanation of function and operation
1. 16-bit operation (LOADR and LOADRP)
The contents (current values) of extension file registers (ER) stored in a memory cassette (flash memory)
having the same numbers with the extension registers specified by
transferred to the extension registers specified by
Command
input
FNC290
LOADRP
Extension file registers (ER)
inside memory cassette
E
S
E
S
+1
E
S
+2
S
E
+3
S
E
+n-2
E
S
+n-1
• Reading and transfer are executed in units of device. Up to 32768 devices can be read and transferred.
• Different from SAVER (FNC291), INITR (FNC292) and LOGR (FNC293) instructions, it is not necessary to
execute this instruction in units of sector.
• If "n" is set to "0", it is handled as "32768" when the instruction is executed.
708
Mnemonic
16-bit Instruction
LOADR
5 steps
LOADRP
Device number of extension register (transfer destination) to which data is to be
transferred
(The extension file register having the same number is handled as the data
transfer source.)
Number of points to be read (transferred) [0 ≤ n ≤ 32767]
Digit Specification
S
n
Extension registers (R)
Read
inside built-in RAM
(transfer)
33 Extension File Register Control – FNC290 to FNC299
Operation Condition
32-bit Instruction
Continuous
Operation
Pulse (Single)
Operation
Description
Word Devices
Special
System User
Unit
V Z Modify K H
to
+n-1 stored in the PLC's built-in RAM.
S
S
S
S
+1
S
+2
S
+3
S
+n-2
S
+n-1
33.1 FNC290 – LOADR / Load From ER
Mnemonic
Operation Condition
Data Type
16-bit binary
Others
Con-
Real
Charac-
Index
stant
Number
ter String
E
" "
to
+n-1 are read, and
S
S
Pointer
P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3uc seriesMelsec-f

Table of Contents