Programming Manual - Basic & Applied Instruction Edition
Number and name
High Speed Counter Up/down Counter Counting Direction (Refer to Section 4.7 for details.)
M 8235
C235
M 8236
C236
M 8237
C237
M 8238
C238
M 8239
C239
M 8240
C240
M 8241
C241
M 8242
C242
M 8243
C243
M 8244
C244
M 8245
C245
High Speed Counter Up/down Counter Monitoring (Refer to Section 4.7 for details.)
[M]8246
C246
[M]8247
C247
[M]8248
C248
[M]8249
C249
[M]8250
C250
[M]8251
C251
[M]8252
C252
[M]8253
C253
[M]8254
C254
[M]8255
C255
[M]8256 to [M]8259
Not used
Analog Special Adapter (Refer to Subsection 36.2.17 for applicability of each analog special adapter.)
*1
1st special adapter
M 8260 to M 8269
*1
2nd special adapter
M 8270 to M 8279
*1
3rd special adapter
M 8280 to M 8289
*1
4th special adapter
M 8290 to M 8299
[M]8300 to [M]8315
Not used
*1.
The unit number of the analog special adapter is counted from the main units side.
*2.
Available in Ver. 1.20 or later.
Unconnected I/O Designation Error (Refer to Chapter 37 for details.) and flag
*3
Unconnected I/O designation error
[M]8316
[M]8317
Not used
BFM initialization failure
ON when a FROM/TO error has occurred in a special
function
initialization function at changing PLC from STOP to
[M]8318
RUN.
When M8318 turns ON, the unit number in which the
error has occurred is stored in D8318, and the BFM
number is stored in D8319.
[M]8319 to [M]8327
Not used
[M]8328
Instruction non-execution
[M]8329
Instruction execution abnormal end
*3.
If the I/O device numbers are unavailable, M8316 turns ON when its directly designated to device
numbers including LD, AND, OR, and OUT instructions or indirectly designated by index.
*4.
Available in Ver. 2.00 or later.
810
Operation and function
When M8
is ON, the corresponding
C
is changed to down mode.
• ON: Down count operation
• OFF: Up count operation
When C
of 1-phase 2-input or 2-phase
2-input counter is in down mode, the
corresponding M8
turns ON.
• ON: Down count operation
• OFF: Up count operation
block/unit
as
specified
36 Operation of Special Devices (M8000 -, D8000 -)
FX
FX
3U
3UC
*2
*2
*2
*2
in
the
BFM
*4
*4
36.1 Special Device List (M8000 -, D8000 -)
Applicable model
Correspond-
ing special
FX
FX
FX
1S
1N
device
D8316
D8317
D8318
D8319
FX
FX
2N
1NC