Mitsubishi FX3U Series Programming Manual page 668

Hide thumbs Also See for FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series Programmable Controllers
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Explanation of function and operation
1. 16-bit operation (SCL and SCLP)
The input value specified in
stored to a device number specified in
stored in a device specified in
If the output data is not an integer, however, a number in the first decimal place is rounded.
Command
input
FNC259
Y
Output
value
(
)
D
Point 1
Operation
error
2. 32-bit operation (DSCL and DSCLP)
The input value specified in [
characteristics, and stored to a device number specified in [
executed based on the data table stored in a device specified in [
If the output data is not an integer, however, a number in the first decimal place is rounded.
Command
input
FNC259
Y
Output
value
(
)
D
Point 1
Operation
error
666
is processed by scaling for the specified conversion characteristics, and
S
1
and later.
S
2
→ For the method to set the conversion table for scaling, refer to the next page.
S
S
1
2
SCL
Point 2
Point 5
Point 3
Point 4
Input value (
S
)
1
Operation is enabled.
+1,
S
1
S
S
1
2
DSCL
Point 2
Point 5
Point 3
Point 4
Input value (
S
)
1
Operation is enabled.
29 Data Table Operation – FNC250 to FNC269
29.4 FNC259 – SCL / Scaling (Coordinate by Point Data)
. Conversion for scaling is executed based on the data table
D
Conversion setting data table for scaling
D
Number of coordinate points
("5" in the case shown in the left
figure)
Point 1
Point 2
X
Operation
Point 3
error
Point 4
Point 5
] is processed by scaling for the specified conversion
S
1
D
S
Conversion setting data table for scaling
D
Number of coordinate points
("5" in the case shown in the left
figure)
Point 1
Point 2
X
Point 3
Operation
error
Point 4
Point 5
Device assignment in
Set item
setting data table
S
2
X coordinate
S
2
Y coordinate
S
2
X coordinate
S
2
Y coordinate
S
2
X coordinate
S
2
Y coordinate
S
2
X coordinate
S
2
Y coordinate
S
2
X coordinate
S
2
Y coordinate
S
2
+1,
]. Conversion for scaling is
D
+1,
] and later.
S
2
2
Device assignment in
Set item
setting data table
[
S
2
X coordinate
[
S
2
Y coordinate
[
S
2
X coordinate
[
S
2
Y coordinate
[
S
2
X coordinate
[
S
2
Y coordinate
[
S
2
X coordinate
[
S
2
Y coordinate
[
S
2
X coordinate
[
S
2
Y coordinate
S
[
2
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+1,
S
]
2
+3,
S
+2]
2
+5,
+4]
S
2
+7,
S
+6]
2
+9,
S
+8]
2
+11,
+10]
S
2
+13,
S
+12]
2
+15,
S
+14]
2
+17,
S
+16]
2
+19,
S
+18]
2
S
+21,
+20]
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3uc seriesMelsec-f