Programming Manual - Basic & Applied Instruction Edition
Program example
In the program example shown below, the contents of extension registers R10 to R19 (sector 0) used for
setting data are reflected on extension file registers (ER) when X000 turns ON.
Program
X000
M0
Operation
Setting data
Extension registers (R)
Device number Current
R0
R1
.
.
.
R10
R11
R12
.
.
.
R19
.
.
.
R99
R100
.
.
.
R2047
PLS
MOV
D8000
D200
ADD
D8000
K66
D8000
FNC 07
WDT
FNC294
R10
K10
RWER
MOVP
D200
D8000
FNC 07
WDT
END
Device number Current
value
K100
K105
.
.
.
K200
K215
K400
.
Write
.
.
(when X000
turns ON)
K350
.
.
.
K1000
HFFFF
.
.
.
HFFFF
33 Extension File Register Control – FNC290 to FNC299
M0
Setting backup data
Extension file registers
(ER)
value
ER0
K100
ER1
K105
.
.
.
.
.
.
ER10
K200
ER11
K215
ER12
K400
.
.
.
.
.
.
ER19
K350
.
.
.
.
.
.
ER99
K1000
ER100
HFFFF
.
.
.
.
.
.
ER2047
HFFFF
33.5 FNC294 – RWER / Rewrite to ER
31