11.3.22 Regenerative load ratio [BFM #65, BFM #165]

The regenerative load ratio power to the maximum regenerative power is stored in percentage.
With regenerative brake option, the regenerative power ratio of the allowable capacity is stored.
BFM Number
X-axis
BFM #65
BFM #165

11.3.23 Effective load torque [BFM #66, BFM #166]

The continuous effective load torque is stored.
This parameter stores the average value of the load ratio to the rated torque (100%) in the past 15 seconds.
BFM Number
X-axis
BFM #66
BFM #166

11.3.24 Peak torque ratio [BFM #67, BFM #167]

The maximum torque during operations is stored.
This parameter stores the peak value to the rated torque (100%) in the past 15 seconds.
BFM Number
X-axis
BFM #67
BFM #167

11.3.25 Servo warning code [BFM #68, BFM #168]

Warnings detected by the servo amplifier are stored.
Clear the cause of warning.

11.3.26 Motor feedback position [BFM #71, #70, BFM #171, #170]

Motor feedback positions are stored.
BFM Number
X-axis
BFM #71,#70

11.3.27 Servo status 2 [BFM #72, BFM #172]

BFM Number
X-axis
BFM #72
BFM #172

11.3.28 Flash memory write count [BFM #91, #90]

The number of times data is written to the flash memory is stored.
BFM Number
X-axis
BFM #91,#90
Note
The maximum number of writes to the built-in flash memory is 100,000 times.
126
Y-axis
Regenerative load ratio (%)
Y-axis
Effective load torque (%)
Y-axis
Peak torque ratio (%)
→ For details on the warnings, refer to the manual of the connected servo amplifier
Y-axis
BFM #171,#170
Motor feedback position (PLS)
Bit
Number
Y-axis
A parameter update completed flag
This bit is set when an automatic update of servo
b0
parameters is completed.
Cleared when a servo parameter save command or
servo parameter initialization command is finished.
b15 to b1
Not available
Y-axis
-
The number of writes to the flash memory
11 Buffer Memory (Parameters & Monitored Data)
Description
Description
Description
→ For details on the warning codes, refer to Subsection 13.2.4
Description
Description
Description
11.3 Monitor Data
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-
Value Format
Default
Bit
-
Value Format
Default
Decimal
-

Advertisement

Table of Contents
loading

Table of Contents