Mitsubishi FX3U Series Programming Manual page 874

Hide thumbs Also See for FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series Programmable Controllers
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Execution time in ON status (µs)
FNC
Instruction
No.
16-bit instruction
Data table processing
250
251
252
253
254
255
256 LIMIT
257 BAND
258 ZONE
259 SCL
260 DABIN
261 BINDA
262
263
264
265
266
267
268
269 SCL2
2.79 + 5.21n
External device communication (inverter communication)
270 IVCK
271 IVDR
272 IVRD
273 IVWR
274 IVBWR
Data move 3
275
276
277
*1
1086n
RBFM
278
*2
244 + 103n
RBFM
*1
1099n
WBFM
279
*2
292 + 116n
WBFM
*1.
When the instruction is executed to a BFM in a special function block/unit for the FX
Series or in the CC-Link/LT built in the FX
*2.
When the instruction is executed to a BFM in a special function block/unit for the FX
High speed processing 2
280 HSCT
281
282
283
284
285
286
287
288
289
872
32-bit instruction
8.1
8.6
8.1
8.6
7.9
8.5
15.9
16.8
13.7
19.5
16.7
23.1
29.06 + 7.94n
14.1
14.1
16.2
16.2
20.0
30.0
Execution time in OFF status (µs)
16-bit instruction
32-bit instruction
0.585
1.105
0.585
1.105
0.585
1.105
0.455
0.845
0.325
0.585
0.325
0.585
0.455
0.845
6.5
6.5
6.5
6.5
6.5
0.715
0.715
0.715
0.715
-32MT-LT
3UC
1.365
B Instruction Execution Time
B-4 Applied Instruction Execution Time
Remarks
n: Number of data
n: Number of points transferred
in one operation cycle
n: Number of points transferred
in one operation cycle
/FX
0N
/FX
3U
/FX
2N
2NC
Series
3UC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3uc seriesMelsec-f