Mitsubishi FX3U Series Programming Manual page 137

Hide thumbs Also See for FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series Programmable Controllers
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Cautions
1) Even if a numeric value written to index registers does not exceed the 16-bit numeric value range (0 to
32767), make sure to overwrite both V and Z using a 32-bit instruction. If only Z is overwritten and
another numeric value remains in V, consequently the numeric value here becomes extremely large.
Thus an operation error occurs.
2) It is not permitted to use 16-bit counters as 32-bit counters by executing indexing.
When 32-bit counters are required as the result of indexing, add Z0 to Z7 to counters C200 and later.
3) It is not permitted to index V and Z themselves.
4) Direct specification of buffer memory in special function blocks/units
In the direct specification of buffer memory "U \G ", the buffer memory number can be indexed with
index register.
The unit number cannot be indexed with index register.
("U0\G0Z0" is valid, but "U0Z0\G0" is invalid.)
5) Indexing in bit digit specification
It is not permitted to index "n" in "Kn" used for digit specification.
("K4M0Z0" is valid, but "K0Z0M0" is invalid.)
6) Indexing of I/O relays (octal device numbers)
When octal device numbers of X, Y, KnX, and KnY are indexed
with index register, the contents of an index register are
converted into octal, and then added to the device number.
In the example shown in the figure on the right, Y007 to Y000
are output by MOV instruction, and inputs are switched by
indexing to X007 to X000, X017 to X010, and X027 to X020.
When rewriting the index value as "K0", "K8", "K16", the device
number converted into octal is added "X000 + 0 = X000", "X000
+ 8 = X10", "X000 + 16 = X20", and the input terminal working as
the source is changed accordingly.
Display example of timer present value
A sequence to display the present value of the timers T0 to T9 can
be programed by index registers.
M8000
RUN monitor
"T0Z0 = T0 to T9" according to "Z0 = 0 to 9"
FNC 19
K1X000
Z0
BIN
(X003 to X000)BCD→(Z0)BIN
FNC 18
T 0Z0
K4Y000
BCD
(T0Z0)BIN→(Y017 to Y000)BCD
5 How to Specify Devices and Constants to Instructions
X030
FNC 12
MOVP
X031
FNC 12
MOVP
X032
FNC 12
MOVP
X033
FNC 12
MOV
: X7 to X0 → Y7 to Y0
V3=0
: X17 to X10 → Y7 to Y0
V3=8
V3=16 : X27 to X20 → Y7 to Y0
Digital switch input
5
for setting timer
number X003 to X000
PLC
Seven-segment display unit
output for displaying
timer current value
Y017 to Y000
5.7 Indexing
1
2
3
4
K 0
V 3
K 0 → V 3
K 8
V 3
K 8 → V 3
5
K 16
V 3
K16 → V 3
K2X0V3
K2Y0
6
7
8
9
10
135