2. Instruction codes of inverters
The table below shows the instruction codes and functions for the inverter specified in
For instruction codes, refer to pages in the inverter manual where the computer link function is explained in
detail.
(Hexadecimal
instruction code of
inverter specified in
S
2
HFB
HF3
HF9
HFA
HEE
HED
HFD
HF4
HFC
HFC
3. Related devices
Number
ch1
ch2
M8029
M8063 M8438 Serial communication error
M8151 M8156 Inverter communicating
M8152 M8157 Inverter communication error
M8153 M8158
M8154 M8159 IVBWR instruction error
*1.
Cleared when the PLC mode switches from STOP to RUN.
*2.
Initial value: -1
Cautions
• It is not permitted to use the RS (FNC 80)/RS2 (FNC 87) instruction and an inverter communication
instruction (FNC270 to FNC274) for the same port.
• Two or more inverter communication instructions (FNC270 to FNC274) can be driven for the same port at
the same time.
Function change depending on the version
Inverter models available in this instruction are added depending on the version as shown in the table below.
Applicable version
FX
3U
Ver.2.00 or later Ver.2.00 or later
30 External Device Communication (Inverter Communication) – FNC270 to FNC274
Written contents
Operation mode
Special monitor selection
number
Operation command
(extension)
Operation command
Set frequency
(written to EEPROM)
Set frequency
(written to RAM)
Inverter reset
Abnormal contents all clear
Parameter all clear
User clear
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
Description
Instruction execution complete
*1
*1
Inverter communication error
*1
latch
*1
→ For other cautions, refer to the Communication Control Manual.
Item
FX
3UC
Addition of applicable
models
30.2 FNC271 – IVDR / Inverter Drive
Corresponding inverter
F700
A700
V500
F500
Number
ch1
ch2
D8063
D8438 Error code of serial communication error
D8150
D8155 Response wait time in inverter communication
D8151
D8156 Step number in inverter communication
Error code of inverter communication
D8152
D8157
*1
error
Latch of inverter communication error
D8153
D8158
occurrence step
D8154
D8159 IVBWR instruction error parameter number
Outline of function
Mitsubishi FREQROL-F700/A700 Series general-purpose
inverters are supported.
.
S
2
A500
E500
S500
Description
*2
*2
685
21
22
23
24
25
26
27
*2
28
29
30