General information
2.6 Technical data
2.6.1.2
SINAMICS V90 PN 400 V variant
General technical data
Parameter
Overload capability
Control system
Dynamic brake
Protective functions
Overvoltage criteria
Certification
Speed control mode
Speed control range
Torque limit
Environmental conditions
Surrounding air
Operation
temperature
Storage
Ambient humidity
Operation
Storage
58
Description
300%
Servo control
Built-in
Earthing fault protection, output short-circuit protection
protection
, drive I
t protection, motor overtemperature protection
2)
2
temperature protection
Category III
Internal speed command 1:5000
Set through a parameter
0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
-40 °C to +70 °C
< 90% (non-condensing)
90% (non-condensing)
, overvoltage/undervoltage
1)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
, IGBT over-
3)