Siemens SINAMICS V90 Operating Instructions Manual page 267

Profinet
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Parameter
Specifications
Description: Inverts the signals at the digital outputs.
Bit 0: inverts signal DO 1
Bit 1: inverts signal DO 2
p0795
Digital inputs simulation mode
Min: 0
Data type: U32
Description: Sets the simulation mode for digital inputs.
Bit 0 to bit 9: set the simulation mode for DI 1 to DI 10
Bit = 0: terminal eval
Bit = 1: simulation
Note: If a digital input is used as signal source for the function "STO" then it is not permissible to select
the simulation mode and this is rejected.
This parameter is not saved when data is backed up.
p0796
Digital inputs simulation mode setpoint
Min: 0
Data type: U32
Description: Sets the setpoint for the input signals in the digital input simulation mode.
Bit 0 to bit 9: set the setpoint for DI 1 to DI 10
Bit = 0: low
Bit = 1: high
Note: This parameter is not saved when data is backed up.
p0922
PROFIdrive: PZD telegram selection
Min: 1
Data type: U16
Description: Sets the send and receive telegram.
For speed control mode:
1: Standard telegram 1, PZD-2/2
2: Standard telegram 2, PZD-4/4
3: Standard telegram 3, PZD-5/9
5: Standard telegram 5, PZD-9/9
102: SIEMENS telegram 102, PZD-6/10
105: SIEMENS telegram 105, PZD-10/10
For basic positioner control mode:
7: Standard telegram 7, PZD-2/2
9: Standard telegram 9, PZD-10/5
110: SIEMENS telegram 110, PZD-12/7
111: SIEMENS telegram 111, PZD-12/12
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
Bit 0 = 0: not inverted
Bit 0 = 1: inverted
Bit 1 = 0: not inverted
Bit 1 = 1: inverted
Max: 4294967295
Effective: IM
Max: 4294967295
Effective: IM
Max: 111
Effective: IM
Factory setting: 0
Can be changed: T, U
Factory setting: 0
Can be changed: T, U
Factory setting: 105
Can be changed: T
Parameters
11.2 Parameter list
Unit: -
Unit: -
Unit: -
265