Safety Integrated function
9.3 System features
9.3
System features
9.3.1
STO functional safety data
The STO functional safety data of SINAMICS V90 PN is as follows:
Applied standards
Type
Safety Integrity Level (SIL)
Hardware Fault Tolerance (HFT)
Probability of Failure per Hour (PFH)
9.3.2
Certification
The safety function of the SINAMICS V90 PN drive system meets the following
requirements:
● Category 3 according to ISO 13849-1:2015
● Performance Level (PL) d to ISO 13849-1:2015
● Safety integrity level 2 (SIL 2) to IEC 61508
In addition, the safety function of SINAMICS V90 PN has been certified by independent
institutes. An up-to-date list of certified components is available on request from your local
Siemens office.
9.3.3
Safety instructions
Note
Residual risks not specified in this section are included in the chapter "Fundamental safety
instructions (Page 13)".
240
IEC 61508, IEC 62061, ISO 13849-1
A
2
1
5 × 10
per hour
-8
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008