Parameter
Name
Dependency: Refer to r2124
Note: The buffer parameters are cyclically updated in the background.
Alarm buffer structure (general principle):
r2122[0], r2124[0] → alarm 1 (the oldest)
...
r2122[7], r2124[7] → alarm 8 (the latest)
When the alarm buffer is full, the alarms that have gone are entered into the alarm history:
r2122[8], r2124[8] → alarm 1 (the latest)
...
r2122[63], r2124[63] → alarm 1 (the oldest)
r2124[0...63]
Alarm value
Description: Displays additional information about the active alarm (as integer number).
Dependency: Refer to r2122
Note: The buffer parameters are cyclically updated in the background.
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
r2521[0...3]
LR position actual value
Description: Display and connector output for the actual position actual value determined by the posi-
tion actual value preprocessing.
Index:
[0]: Cl-loop position control
[1]: Encoder 1
[2]: Encoder 2
[3]: Reserved
r2556
LR position setpoint after setpoint smoothing
Description: Display and connector output for the position setpoint after setpoint smoothing.
r2563
LR following error dynamic model
Description: Display and connector output for the dynamic following error.
This value is the deviation, corrected by the velocity-dependent component, between the position set-
point and the position actual value.
r2665
EPOS position setpoint
Description: Displays the actual absolute position setpoint.
r8909
PROFIdrive: Device ID
Description: Displays the PROFINET device ID.
Every SINAMICS device type has its own PROFINET device ID and its own PROFINET GSD.
r8930[0...239]
PROFIdrive: Active name of station
Description: Displays the active station name for the onboard PROFINET interface on the Control Unit.
r8931[0...3]
PROFIdrive: Active IP address of station
Description: Displays the active IP address for the onboard PROFINET interface on the Control Unit.
r8932[0...3]
PROFIdrive: Active default gateway of station
Description: Displays the active default gateway for the onboard PROFINET interface on the Control
Unit.
r8933[0...3]
PROFIdrive: Active subnet mask of station
Description: Displays the active subnet mask for the onboard PROFINET interface on the Control Unit.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
Parameters
11.2 Parameter list
Unit
Data type
-
I32
LU
I32
LU
I32
LU
I32
LU
I32
-
U16
-
U8
-
U8
-
U8
-
U8
303