Parameters
11.2 Parameter list
Parameter
Specifications
p1659 *
Current setpoint filter 1 denominator damping
Min: 0.001
Data type: Float
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1658 ...
p1659.
p1663
Current setpoint filter 2 denominator natural frequency
Min: 0.5
Data type: Float
Description: Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1664
Current setpoint filter 2 denominator damping
Min: 0.001
Data type: Float
Description: Sets the denominator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1665
Current setpoint filter 2 numerator natural frequency
Min: 0.5
Data type: Float
Description: Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1666
Current setpoint filter 2 numerator damping
Min: 0.000
Data type: Float
Description: Sets the numerator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1668
Current setpoint filter 3 denominator natural frequency
Min: 0.5
Data type: Float
Description: Sets the denominator natural frequency for current setpoint filter 3 (PT2, general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1669
Current setpoint filter 3 denominator damping
Min: 0.001
Data type: Float
Description: Sets the denominator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1670
Current setpoint filter 3 numerator natural frequency
Min: 0.5
Data type: Float
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
274
Max: 10.000
Effective: IM
Max: 16000.0
Effective: IM
Max: 10.000
Effective: IM
Max: 16000.0
Effective: IM
Max: 10.000
Effective: IM
Max: 16000.0
Effective: IM
Max: 10.000
Effective: IM
Max: 16000.0
Effective: IM
Factory setting: 0.700
Can be changed: T, U
Factory setting: 1000.0
Can be changed: T, U
Factory setting: 0.300
Can be changed: T, U
Factory setting: 1000.0
Can be changed: T, U
Factory setting: 0.010
Can be changed: T, U
Factory setting: 1000.0
Can be changed: T, U
Factory setting: 0.300
Can be changed: T, U
Factory setting: 1000.0
Can be changed: T, U
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
Unit: -
Unit: Hz
Unit: -
Unit: Hz
Unit: -
Unit: Hz
Unit: -
Unit: Hz