Siemens SINAMICS V90 Operating Instructions Manual page 301

Profinet
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Parameter
Name
r0632
Motor temperature model, stator winding temperature
Description: Displays the stator winding temperature of the motor temperature model.
r0722
CU digital inputs status
Description: Displays the status of the digital inputs.
Note:
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
The drive unit displays the value in hex format. You can convert the hex number to the binary number,
for example, FF (hex) = 11111111 (bin).
r0747
CU digital outputs status
Description: Displays the status of digital outputs.
Note:
DI/DO: Bidirectional Digital Input/Output
The drive unit displays the value in hex format. You can convert the hex number to the binary number,
for example, FF (hex) = 11111111 (bin).
r0930
PROFIdrive operating mode
Description: Displays the operating mode.
1: Closed-loop speed controlled operation with ramp-function generator
2: Closed-loop position controlled operation
3: Closed-loop speed controlled operation without ramp-function generator
r0945[0...63]
Fault code
Description: Displays the number of faults that have occurred.
Dependency: Refer to r0949
Note: The buffer parameters are cyclically updated in the background.
Fault buffer structure (general principle):
r0945[0], r0949[0] → actual fault case, fault 1
...
r0945[7], r0949[7] → actual fault case, fault 8
r0945[8], r0949[8] → 1st acknowledged fault case, fault 1
...
r0945[15], r0949[15] → 1st acknowledged fault case, fault 8
...
r0945[56], r0949[56] → 7th acknowledged fault case, fault 1
...
r0945[63], r0949[63] → 7th acknowledged fault case, fault 8
r0949[0...63]
Fault value
Description: Displays additional information about the fault that occurred (as integer number).
Dependency: Refer to r0945
Note: The buffer parameters are cyclically updated in the background.
The structure of the fault buffer and the assignment of the indices is shown in r0945.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
Parameters
11.2 Parameter list
Unit
Data type
°C
Float
-
U32
-
U32
-
U16
-
U16
-
I32
299