Honeywell Fusion4 MSC-L Installation & Operation Manual page 384

Table of Contents

Advertisement

Entity
[RIT red lamp]
[RIT green lamp]
[RIT amber lamp]
[Ready lamp]
Entity
[Batch preset quantity]
[Loading type]
[Batch initial quantity]
[Batch pre-stop quantity]
[Batch clean arm quantity]
5 - 196
Operation - Arm Configuration
Description
With this entity you can select the
physical output for the RIT red lamp
function.
With this entity you can select the
physical output for the RIT green lamp
function.
With this entity you can select the
physical output for the RIT amber lamp
function.
With this entity you can select the
physical output which conveys whether the
load is ready to start, when all permissive are
met.
5.15.3 Arm Configuration . Arm n . Control Settings
On the Arm Configuration . Arm n screen, select
The Arm Configuration . Arm n . Control Settings screen is
displayed with the following entities.
Description
With this entity the total final required
GOV of the blended product is
obtained. This value is either entered
directly by the user or supplied
externally by the TAS.
With this entity you can select the blend
type for the loading process, as well as
use it for unloading purposes.
With this entity you can determine the
amount of product that must be
delivered into the compartment at the
Initial Flow Rate to ensure that the risk
of static discharge is eliminated.
With this entity you can determine the
volume before the end of the batch at
which the flow rate must be adjusted to
dispense the exact quantity requested.
With this entity the amount of the
unblended main product at the end of a
batch can be determined. The flow rate
to obtain this volume is not defined,
though it is still restricted due to the
limitations mentioned previously.
However, blending during delivering the
clean arm volume is not permitted.
Fusion4 MSC-L
Installation & Operation Manual
Can be linked to...
Any one of unused Digital Outputs (DO-
SSR-n or DO-EMR-n), Pulse Outputs (PO-
n), or None.
Any one of unused Digital Outputs (DO-
SSR-n or DO-EMR-n), Pulse Outputs (PO-
n), or None.
Any one of unused Digital Outputs (DO-
SSR-n or DO-EMR-n), Pulse Outputs (PO-
n), or None.
Any one of unused Digital Outputs (DO-
SSR-n or DO-EMR-n), Pulse Outputs (PO-
n), or None.
<Control
Value range
<0.00> L
default =
<Ratio>
(default)
<Side stream>
<Unloading>
<Straight with VRU>
<Sequential>
<0> L to <1000000> L
<300> L
(default =
)
<0> L to <1000000> L
<300> L
(default =
)
<0> L to <1000000> L
<300> L
(default =
)
Part No.: 4418309_Rev09
settings>.