5.11.2.3.4 Stream Configuration - Stream n - Alarms
5.11.3.1 System Configuration
Part No.: 4418309_Rev09
Honeywell
Operation - Interfacing With External Additive Controller
2. On the Stream Config - Stream n - Additive Control screen, set
<Additive mode>
It is recommended to choose the alarm action on MSC- A as display
and choose the required action on MSC L. This will cause the action to
apply to whole batch and the streams that it contains and not just the
additive stream.
When any alarm is cleared from MSC-A, it will automatically be cleared
from MSC-L screen as well. If a no activity timeout alarm on the MSC-A is
cleared from the MSC-L, a disable permissive command shall be sent to
that stream if there is no batch with that stream running on the MSC-L.
5.11.3 Configuring MSC-L
This section describes how to configure the MSC-L to interface with
External Additive Injector.
To connect the external injectors,
Use COM1 or COM2 ports for External Injectors 1 - 12.
Use COM6 or COM7 ports for External Injectors 13 - 24.
Up to six external additive streams are qualified to be used with a single
COM port.
To perform the system configuration
1. On the Main Menu screen, select the System Configuration icon.
The System Configuration screen appears, which displays the
functions available for system configuration.
Fusion4 MSC-L
Installation & Operation Manual
<Smart>.
entity value as
5 - 83