Entity
[Feedback mode]
[Feedback pulse duration]
Pump run timeout]
[
[Block valve location]
[Factored pulse width]
5.14.2.3.2 Solenoid
Entity
[Number of retries]
[Close delay]
Part No.: 4418309_Rev09
Honeywell
Operation - Stream Configuration
Description
With this entity you can select the type
of feedback for each injection.
With this entity you can enter the
duration of the feedback pulse in ms.
With this entity you can enter the time
in minutes between the last injection
and the additive pump stop.
With this entity you can configure the
physical position of the block valve
pertaining to the additive meter.
On the Additive Stream Config. - Stream n- Control Settings screen,
select <Solenoid>.
The Additive Stream Config. - Stream n - Solenoid screen is
displayed with the following entities.
Description
With this entity you can set the number
of retries for opening the solenoid
again, in case additive pulses are not
received.
With this entity you can set the time in
ms. The additive pulses must be
stopped after the solenoid is closed.
Fusion4 MSC-L
Installation & Operation Manual
Value range
<None>
(default)
<end sensor piston emul.>
<Piston switch>
<inv.end-sensor piston emul.>
<Inverted piston switch>
<mid-stroke piston emul.>
<Post injection>
<Double pulse>
<Last 25%>
<Ext. piston switch>
<Inv. ext. piston switch>
<0>
<1000>
ms ...
ms
<500> ms
(default =
)
<1>
<255>
min ...
mins
<10>
(default =
mins)
<Upstream from meter>
<Downstream from meter>
Value range
<0>
<2>
...
<2>
(default =
)
<500>
<10000>
ms ...
ms
<500> ms
(default =
)
from (default)
5 - 181