Honeywell Fusion4 MSC-L Installation & Operation Manual page 349

Table of Contents

Advertisement

5.14.1.4.2.8 Volume Conversion Terms
5.14.1.4.2.9 Calculation of Gross Standard Volume
Part No.: 4418309_Rev09
Honeywell
Operation - Stream Configuration
product (lab sample) density
lab
T
product (lab sample) temperature
ab
P
product (lab sample) pressure
lab

product thermal expansion factor at 60 °F
product (metering conditions) density (measured or calculated)
m
T
product (metering conditions) temperature
m
P
product (metering conditions) pressure
m
V
product (metering conditions) volume
m
product (base conditions) density
b
T
product (base conditions) temperature
b
P
product (base conditions) pressure
b
V
product (base conditions) volume
b
M
product mass
P
product equilibrium vapour pressure
e
F
product compressibility factor
p
CTL
temperature correction factor from conditions A to conditions B
A-B
CPL
pressure correction factor from conditions A to conditions B
A-B
CTPL
temperature and pressure correction factor from conditions A to
A-B
conditions B
The calculation of the Gross Standard Volume (GSV) is performed
incrementally by performing a volume-conversion calculation on an
incremental measured product stream volume. The volume-converted
values of these incremental product stream observed volumes are then
added together to generate the running accumulative GSV value.
The gross standard volume after N number of incremental calculation
intervals is provided by the following formula.
N
GSV
VCF
transactio
n
1
i
The GOV
represents the total accumulative gross observed volume
i
after i calculation intervals. GOV
Fusion4 MSC-L
Installation & Operation Manual
(
)
GOV
GOV
1
i
i
i
is always 0.
0
5 - 161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enraf fusion4 msc-l

Table of Contents