5 - 92
Operation - Sequential Blending Overview
5.12.1 Configuration
The following parameters need to be set to achieve Sequential
blending.
1. In the Arm where Sequential Blending is needed, Assign the desired
streams to the loading Arm and Set
 Arm Configuration | Arm x | Control settings |
<Sequential blending>
 Arm Configuration | Arm x | Control settings |
<0 - 99 s>
Only streams belonging to same Arm board should be assigned to
loading arm on the same board for Sequential Blending loading type.
e.g Stream 1-6 are on Arm board 1 and Streams 7-12 on Arm Board
2. With XL6 license, Loading Arms 1-3 shall be on Arm board 1 and
Loading Arms 4-6 on Arm board 2. So, if we need Sequential
blending on say loading Arm 5 which is on Arm board 2, only the
streams 7-12 which are on same board should be assigned to this
loading Arm.
2. In one of the Streams being Sequentially Blended, Set
 Stream Configuration | Stream y | I/O bindings | Inputs |
meter]
 Stream Configuration | Stream y | I/O bindings
[Temperature]
 Stream Configuration | Stream y | I/O bindings | Inputs |
<AI-x>
=
 Stream Configuration | Stream y | I/O bindings | Inputs | [Density]
<AI-x>
=
 Stream Configuration | Stream y | I/O bindings | Outputs |
<DO-SSR-x, PO-x, DO-EMR-x>
=
 Stream Configuration | Stream y | I/O bindings | Outputs |
<DO-SSR-x, PO-x, DO-EMR-x>
=
 Stream Configuration | Stream y | I/O bindings | Outputs |
Flow 2SV]
 Stream Configuration | Stream y | I/O bindings | Outputs |
Flow 2SV]
 Stream Configuration | Stream y | I/O bindings | Outputs |
lation NO DCV]
 Stream Configuration | Stream y | I/O bindings | Outputs |
lation NC DCV]
 Stream Configuration | Stream y | I/O bindings | Outputs |
< AO-x>
=
3. Control Settings.Valve Control needs to be set on the stream with
the shared bindings
4. Settings in 2 and 3 must be left unconfigured in other streams
sharing the Flow meter
Fusion4 MSC-L
Installation & Operation Manual
<QPI-x>
=
.
<AI-x, RTD-x>
=
=
<DO-SSR-x, PO-x, DO-EMR-x>
<DO-SSR-x, PO-x, DO-EMR-x>
=
<DO-SSR-x, PO-x, DO-EMR-x>
=
<DO-SSR-x, PO-x, DO-EMR-x>
=
[Loading type]
[Batch lineup time]
| Inputs |
[Pressure]
[NO DCV]
[NC DCV]
[Recircu-
[Recircu-
[ACV]