11.6

Output terminal function selection

Use the following parameters to change the functions of the open collector output terminals and relay output terminals.
Pr.
190
RUN terminal
M400
function selection
191
NET Y2 output
M404
selection
192
A,B,C terminal
M405
function selection
193
NET Y1 output
M451
selection
194
NET Y2 output
M452
selection
195
NET Y3 output
M453
selection
196
NET Y4 output
M454
selection
313
DO0 output
*2
selection
M410
314
DO1 output
*2
selection
M411
315
DO2 output
*2
selection
M412
316
DO3 output
*2
selection
M413
317
DO4 output
*2
selection
M414
318
DO5 output
*2
selection
M415
319
DO6 output
*2
selection
M416
320
RA1 output selection
*2
M420
321
RA2 output selection
*2
M421
322
RA3 output selection
*2
M422
Pr.
Name
289
Inverter output terminal
M431
filter
*1
The setting range differs depending on the model. For the details, refer to Output signal list.
*2
The setting is available when the PLC function is enabled. (Pr.313 to Pr.315 are always available for settings in the Ethernet model.)
 Assignment of output signals
• The signals can be assigned to the open collector output terminals (2 terminals) and relay output terminal (1 terminal),
which are provided as the output terminals of the inverter. (The open collector output terminals are provided only with the
standard model.)
250
11. (M) Item and Output Signal for Monitoring
11.6 Output terminal function selection
Initial
Name
value
0
For open
collector output
terminal
4
For relay output
99
terminal
Virtual output
terminal for
9999
communication
operation
9999
9999
9999
9999
9999
For terminal on
the option
9999
9999
0
1
4
Initial
Setting range
value
5 to 50 ms
9999
9999
Signal name
0, 1, 3, 4, 7, 8, 11 to 16, 20, 25, 26, 34, 35, 39 to
RUN (Inverter running)
41, 44 to 48, 57, 64, 70, 80, 81, 90 to 93, 95, 96,
98, 99, 100, 101, 103, 104, 107, 108, 111 to 116,
120, 125, 126, 134, 135, 139 to 141, 144 to 148,
FU (Output frequency
157, 164, 170, 180, 181, 190 to 193, 195, 196,
detection)
198, 199, 206, 211 to 213, 242, 306, 311 to 313,
342, 9999
0, 1, 3, 4, 7, 8, 11 to 16, 20, 25, 26, 34, 35, 39 to
41, 44 to 48, 57, 64, 70, 80 to 82, 90, 91, 95, 96,
98, 99, 100, 101, 103, 104, 107, 108, 111 to 116,
120, 125, 126, 134, 135, 139 to 141, 144 to 148,
ALM (Fault)
157, 164, 170, 180 to 182, 190, 191, 195, 196,
198, 199, 206, 211 to 213, 242, 306, 311 to 313,
342, 9999
0, 1, 3, 4, 7, 8, 11 to 16, 20, 25, 26, 34, 35, 39 to
41, 44 to 48, 57, 64, 70, 80, 81, 90 to 93, 95, 98,
99, 100, 101, 103, 104, 107, 108, 111 to 116,
120, 125, 126, 134, 135, 139 to 141, 144 to 148,
No function
157, 164, 170, 180, 181, 190 to 193, 195, 198,
199, 206, 211 to 213, 242, 306, 311 to 313, 342,
9999
No function
No function
0, 1, 3, 4, 7, 8, 11 to 16, 20, 25, 26, 34, 35, 39,
No function
40, 41, 44 to 48, 57, 64, 70, 80, 81, 90 to 93, 95,
96, 98, 99, 100, 101, 103, 104, 107, 108, 111 to
116, 120, 125, 126, 134, 135, 139, 140, 141, 144
No function
to 148, 157, 164, 170, 180, 181, 190 to 193, 195,
196, 198, 199, 206, 211 to 213, 242, 306, 311 to
No function
313, 342, 9999
No function
No function
RUN (Inverter running)
0, 1, 3, 4, 7, 8, 11 to 16, 20, 25, 26, 34, 35, 39,
40, 41, 44 to 48, 57, 64, 70, 80, 81, 90, 91, 95,
SU (Up to frequency)
96, 98, 99, 206, 211 to 213, 242, 9999
FU (Output frequency
detection)
Set the time delay for the output terminal response.
No filtering of the output terminal.
Setting range
*1
*1
*1
*1
Description
*1