Command
Condition
interface
Pr.551 = "3, 9999"
USB
connector
Other than the
above
Pr.550 = "0, 9999"
Option
Other than the
above
Pr.550 = "5" or
Pr.550 = "9999"
(communication
option is not
installed)
Ethernet
connector
Other than the
above
External
control
—
circuit
terminal
○: Controllable, ×: Uncontrollable, Δ: Partially controllable, —: No function
*1
Operation when the enclosure surface operation panel (FR-PA07) is used.
*2
RS-485 communication via PU connector
*3
Only PU stop is enabled. "PS" is displayed on the operation panel during PU stop. The operation follows the Pr.75 Reset selection/
disconnected PU detection/PU stop selection setting. (Refer to
*4
The operation follows the Pr.338 Communication operation command source and Pr.339 Communication speed command source
settings. (Refer to
page
*5
Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to
Item
PU
operation
Operation command
○
(start, stop)
Frequency setting
○
Monitor
○
*5
Parameter write
○
Parameter read
○
Inverter reset
○
Operation command
×
(start, stop)
Frequency setting
×
Monitor
○
*6
Parameter write
×
Parameter read
○
Inverter reset
○
Operation command
×
(start, stop)
Frequency setting
×
Monitor
○
*6
Parameter write
×
Parameter read
○
Inverter reset
×
Operation command
*6
×
(start, stop)
*6
Frequency setting
×
Monitor
○
*6
Parameter write
×
Parameter read
○
*6
Inverter reset
×
Operation command
×
(start, stop)
Frequency setting
×
Monitor
○
*6
Parameter write
×
Parameter read
○
Inverter reset
×
Operation command
×
(start, stop)
Frequency setting
×
Monitor
○
Parameter write
×
Parameter read
○
Inverter reset
×
Operation command
×
(start, stop)
Frequency setting
×
Inverter reset
○
185.)
9.3 Start command source and frequency command source during communication operation
Controllability in each operation mode
Combined
Combined
External
operation
operation
operation
mode 1
mode 2
(Pr.79 = "3")
(Pr.79 = "4")
×
×
○
×
○
×
○
○
○
*6
○
○
×
○
○
○
○
○
○
×
×
×
×
×
×
○
○
○
*6
*6
*6
×
×
×
○
○
○
○
○
○
×
×
×
×
×
×
○
○
○
*6
*6
*6
×
×
×
○
○
○
×
×
×
*6
*6
*6
×
×
×
*6
*6
*6
×
×
×
○
○
○
*6
*6
*6
×
×
×
○
○
○
*6
*6
*6
×
×
×
×
×
×
×
×
×
○
○
○
*6
*6
×
×
×
○
○
○
×
×
×
×
×
×
×
×
×
○
○
○
×
×
×
○
○
○
×
×
×
○
○
×
*8
○
○
Δ
○
○
○
page
128.)
9. (D) Operation Command and Frequency Command
NET
operation
NET
(when the
operation
PU/Ethernet
(via option)
connector
is used)
×
×
×
×
○
○
*6
*6
×
×
○
○
○
○
×
×
×
×
○
○
*6
*6
×
×
○
○
○
○
*4
—
○
*4
—
○
○
○
*5
—
○
○
○
*6
○
×
*6
—
×
*6
—
×
○
○
—
○
○
○
*6
—
×
○
—
○
—
○
○
*5
—
○
○
○
*7
—
○
—
×
—
×
○
○
*6
—
×
○
○
—
×
*4
*4
×
×
*4
*4
×
×
○
○
page
135.)
189