11.1 Speed Indication And Its Setting Change To Rotations Per Minute - Mitsubishi Electric 800 Series Instruction Manual

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

11
(M) Item and Output Signal for Monitoring
Purpose
To display the motor speed (the
number of rotations per minute).
To switch the unit of measure to set
the operation speed from frequency
to motor speed.
To change the item monitored on the
operation panel
To change the monitor item whose
data is output via terminal FM or AM
To adjust the output via terminal FM
or AM
To check the effects of energy saving Energy saving monitoring
To assign functions to the output
terminals
To detect the output frequency
To detect the output current
To detect the output torque
To use the remote output function
11.1
Speed indication and its setting change to
rotations per minute
The frequency monitored or set on the operation panel can be changed to the motor speed or the machine speed.
Pr.
Name
37
Speed display
M000
Frequency / rotation
53
speed unit
M003
switchover
505
Speed setting
M001
reference
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
*2
The setting ranges of Pr.1 (Pr.18), Pr.37, and Pr.505 are limited so that the following formula is satisfied.
Pr.1 (Pr.18) × Pr.37 / Pr.505< 8388.607
The setting range of Pr.1 (Pr.18) is not limited when the machine speed display is not selected. To display the machine speed, set values which
satisfy the formula.
226
11. (M) Item and Output Signal for Monitoring

11.1 Speed indication and its setting change to rotations per minute

Speed indication and its
setting change to rotations
per minute
Operation panel monitor item
selection
clearing the cumulative value
during monitoring
Terminal FM/AM function
selection
Terminal FM/AM calibration
Output terminal function
assignment
Up-to-frequency sensitivity
Output frequency detection
Low speed detection
Output current detection
Zero current detection
Output torque detection
Remote output
*1
Initial value
Setting range
Gr.1
Gr.2
0
1800
0.01 to 9998
0
0
1
4
60 Hz
50 Hz
1 to 590 Hz
Parameter to set
P.M000, P.M001,
Pr.37, Pr.53, Pr.505
P.M003
Pr.52, Pr.170,
P.M020 to P.M023,
Pr.171, Pr.268,
P.M030, P.M031,
Pr.290, Pr.563,
P.M044, P.M050 to
Pr.564, Pr.774 to
P.M052, P.M100 to
Pr.776, Pr.891,
P.M104
Pr.992, Pr.1106 to
Pr.1108
P.M040 to P.M042,
Pr.54, Pr.55, Pr.56,
P.M044, P.M300,
Pr.158, Pr.290,
P.M301
Pr.866
P.M310, P.M320,
Pr.867, C0, C1,
P.M321, P.M390
Pr.1200
P.M023, P.M100,
Pr.52, Pr.54, Pr.158,
P.M200 to P.M207,
Pr.891 to Pr.899
P.M300, P.M301
P.M400, P.M404,
P.M405, P.M410 to
Pr.190 to Pr.196,
P.M416, P.M420 to
Pr.289, Pr.313 to
P.M422, P.M431,
Pr.322
P.M451 to P.M454
P.M440 to P.M443,
Pr.41 to Pr.43,
P.M446
Pr.865 to Pr.870
P.M433, P.M460 to
Pr.150 to Pr.153,
P.M464
Pr.166, Pr.167
P.M470
Pr.864
P.M500 to P.M502
Pr.495 to Pr.497
Monitoring and setting of frequency
Set a number for the speed of machine operated at
*2
the speed (frequency) set in Pr.505.
Frequency displayed
Rotation speed displayed
Machine speed displayed
*2
Set the reference speed (frequency) for Pr.37.
page
82).
Refer to page
226
228
237
241
244
250
257
260
262
263
Description