Mitsubishi Electric 800 Series Instruction Manual page 252

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• The signals can be output via communication, or assigned to the extension terminals of the plug-in option (FR-A8AY or
FR-A8AR).
External output terminal
Terminal
Pr.
name
FR-E800
190
RUN
191
FU
192
A,B,C
193
NET Y1
194
NET Y2
195
NET Y3
196
NET Y4
313
DO0
314
DO1
315
DO2
316
DO3
317
DO4
318
DO5
319
DO6
320
RA1
321
RA2
322
RA3
○: Assignment/output available, ─: Assignment/output unavailable (no function)
*1
The communication protocol affects which terminal can be used. For details, refer to the Instruction Manual (Communication) or the Instruction
Manual of the communication option.
*2
Refer to the Instruction Manual of the option for details on the option output terminals.
 Output signal list
• A function listed below can be set to each output terminal.
• Refer to the following table and set the parameters. (0 to 99, 200 to 299: Positive logic, 100 to 199, 300 to 399: Negative
logic)
Setting
Signal
Positive
Negative
name
logic
logic
0
100
RUN
1
101
SU
3
103
OL
4
104
FU
7
107
RBP
8
108
THP
11
111
RY
12
112
Y12
13
113
Y13
(physical terminal)
communication
FR-E800-E
Function
Output during operation when the inverter
Inverter running
output frequency reaches Pr.13 Starting
frequency or higher.
Output when the output frequency reaches
*1
Up to frequency
the set frequency.
Output while the stall prevention function
Overload warning
works.
Output when the output frequency reaches
Output frequency
the frequency set in Pr.42 (Pr.43 during
detection
reverse rotation) or higher.
Regenerative brake
Output when the regenerative brake duty
prealarm
reaches 85% of the setting of Pr.70.
Output when the cumulative electronic
thermal O/L relay value reaches 85% of the
Electronic thermal O/L
trip level. (The electronic thermal O/L relay
relay pre-alarm
function (E.THT/E.THM) is activated when
the value reaches 100%.)
Output when the reset process is completed
after powering ON the inverter or when the
Inverter operation ready
inverter is ready to start operation with the
start signal ON or during operation.
Output when the output current is higher
Output current detection
than the Pr.150 setting for the time set in
Pr.151 or longer.
Output when the output current is lower than
Zero current detection
the Pr.152 setting for the time set in Pr.153
or longer.
Option output terminal (physical
Output via
terminal)
*1
FR-A8AY
Operation
11. (M) Item and Output Signal for Monitoring
*2
FR-A8AR
Related
Refer to page
parameter
254
Pr.41
257
Pr.22, Pr.23,
214
Pr.66, Pr.154
Pr.42, Pr.43
257
Pr.70
386
Pr.9
198
254
Pr.150, Pr.151
260
Pr.152, Pr.153
260
11.6 Output terminal function selection