Mitsubishi Electric 800 Series Instruction Manual page 232

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Increment
Monitor item
and unit
32-bit cumulative
1 kWh
energy (lower 16 bits)
32-bit cumulative
1 kWh
energy (upper 16 bits)
32-bit cumulative
0.01 kWh
energy (lower 16 bits)
32-bit cumulative
0.01 kWh
energy (upper 16 bits)
BACnet valid APDU
1
counter
PID manipulated
0.1%
amount
Dancer main set
0.01 Hz
speed
*1
The monitor code is used for the Mitsubishi inverter protocol, CC-Link, CC-Link IE TSN, and CC-Link IE Field Network Basic.
*2
The monitor code is used for the MODBUS RTU, MODBUS/TCP, and BACnet/IP.
*3
Indication with a minus sign is not possible via RS-485 communication (Mitsubishi inverter protocol or MODBUS RTU).
*4
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
*5
The actual operation time does not increase if the cumulative running time before power OFF is less than an hour.
*6
Since each readout of the output voltage and output current displayed on the operation panel is a 4-digit number, a value of more than "9999" is
displayed as "----".
*7
The inverter regards the output current which is less than the specified current level (5% of the rated inverter current) as 0 A. Therefore, each
readout of an output current and output power may show "0" if a too small-capacity motor is used as contrasted with the inverter capacity and the
output current falls below the specified value.
*8
Available when the plug-in option is connected.
*9
The details of bits for the input terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
-
b15
Ethernet model
-
-
-
*10 The details of bits for the output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
-
b15
Ethernet model
-
-
-
*11 The details of bits for the option input terminal status 1 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX.) Every bit is 0
(OFF) when the option is not installed.
b15
X15
X14
X13
*12 The details of bits for the option input terminal status 2 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX. "—" denotes an
indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
-
*13 The details of bits for the option output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AY/A8AR. "—" denotes
an indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
-
*14 The increment varies depending on the Pr.53 setting. (Refer to
*15 The monitored values are retained even if an inverter fault occurs. Resetting clears the retained values.
 Monitor display for operation panel (Pr.52, Pr.774 to Pr.776)
• When Pr.52 = "0" (initial value), the monitoring of output frequency, output current, output voltage and fault display can be
selected in sequence by pressing the SET key.
• The Load meter, motor excitation current and motor load factor are displayed on the second monitor (output current)
position, among the monitors set in Pr.52. Other monitors are displayed in the third monitor (output voltage) position.
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
H4D
40277
H4E
40278
H4F
40279
H50
40280
83
H53
40283
91
H5B
40291
*14
97
H61
40297
-
-
RES
-
-
-
-
-
-
-
-
-
-
-
-
-
X12
X11
X10
X9
-
-
-
-
-
-
-
RA3
Negative
indication
*3
*2
(-)
The upper or lower 16 bits of the 32-bit cumulative
energy is displayed on each indication.
Monitoring via communication is available.
The count of valid APDU detection is displayed.
(Available only for the FR-E800-EPA.)
The PID control manipulated amount is displayed.
(Refer to
page
338.)
The set speed for main speed during the dancer control
operation is displayed.
MRS
-
RH
RM
-
-
-
-
-
-
SO
ABC
-
SO
-
ABC
X8
X7
X6
X5
-
-
-
-
RA2
RA1
Y6
Y5
page
226).
11. (M) Item and Output Signal for Monitoring
11.2 Monitor item selection on operation panel or via communication
Description
RL
-
-
STR
STF
-
-
-
DI1
-
-
-
FU
RUN
-
-
-
-
X4
X3
X2
X1
-
-
-
-
Y4
Y3
Y2
Y1
11
12
13
14
15
16
17
18
b0
19
b0
DI0
20
b0
b0
-
b0
X0
b0
DY
b0
Y0
231