Mitsubishi Electric 800 Series Instruction Manual page 403

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

17
Appendix
APPENDIX provides the reference information for use of this product.
Refer to APPENDIX as required.
17.1
For customers replacing the conventional model
with this inverter
17.1.1 Replacement of the FR-E700 series
 Differences and compatibility with the FR-E700 series
Item
Applicable rating
Overload
current rating
Built-in brake transistor
magnetic flux
vector control
General-purpose
Control method
magnetic flux
vector control
Real sensorless
vector control
PM sensorless
vector control
Speed control
Control mode
Torque control
Output frequency
Frequency
setting
resolution
Via terminal FM
(pulse output)
Output signal
Via terminal AM
(analog output)
Operation panel
Main circuit terminals
402
17. Appendix
17.1 For customers replacing the conventional model with this inverter
Two ratings (LD/ND)
ND rating
150% 60 s, 200% 3 s at surrounding air temperature of 50°C
120% 60 s, 150% 3 s at surrounding air temperature
LD rating
of 50°C
Provided in FR-E820-0030(0.4K) to 0330(7.5K),
FR-E840-0016(0.4K) to 0170(7.5K),
FR-E860-0017(0.75K) to 0120(7.5K)
Soft-PWM control / High carrier frequency PWM control
V/F control
Available
Advanced
Available
Not available
Available
Available
Available
Available
0.2 to 590 Hz (under V/F control)
0.2 to 400 Hz (under other than V/F control)
0.015 Hz / 0 to 60 Hz (0 to 10 V / 12 bits)
Terminal 2
0.03 Hz / 0 to 60 Hz (0 to 5 V / 11 bits)
0.03 Hz / 0 to 60 Hz (0 to 20 mA / 11 bits)
0.015 Hz / 0 to 60 Hz (0 to 10 V / 12 bits)
Terminal 4
0.03 Hz / 0 to 60 Hz (0 to 5 V / 11 bits)
0.03 Hz / 0 to 60 Hz (0 to 20 mA / 11 bits)
1440 pulses/s at full scale (FM type only)
-10 to +10 V / 12 bits (AM type only)
Standard
Operation panel installed as standard (not removable).
equipment
7-segment LED 4-digit display.
Option
Enclosure surface operation panel (FR-PA07)
R, S, T, U, V, W, P, PR, N, P1, earth (ground) (screw terminal)
FR-E800
FR-E700
Not available (ND only)
Not available
Provided in FR-E720-030(0.4K) to 330(7.5K),
FR-E740-016(0.4K) to 170(7.5K)
Available
Not available
Not available
Not available
0.2 to 400 Hz
0.06 Hz / 0 to 60 Hz (0 to 10 V / 10 bits)
0.12 Hz / 0 to 60 Hz (0 to 5 V / 9 bits)
0.06 Hz / 60 Hz (0 to 10 V / 10 bits)
0.12 Hz / 60 Hz (0 to 5 V / 9 bits)
0.06 Hz / 60 Hz (0 to 20 mA / 10 bits)
1440 pulses/s at full scale (FR-E700)
0 to +10 V (FR-E700-NA/EC/CHT)
Enclosure surface operation panel (FR-PA07)
Parameter unit (FR-PU07(BB))

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800