NOTE
• The stop selection setting is disabled when the following functions are operating.
Power failure stop function (Pr.261)
PU stop (Pr.75)
Deceleration stop due to communication error (Pr.502)
• When Pr.250 ≠ "9999 or 8888", acceleration/deceleration is performed in accordance to the frequency command until the
output is shut off by turning OFF the start signal.
• When the restart signal is turned ON during the motor coasting, the operation is resumed from Pr.13 Starting frequency.
Parameters referred to
Pr.7 Acceleration time, Pr.8 Deceleration
Pr.13 Starting
frequencypage
169,
Pr.75 Reset selection/disconnected PU detection/PU stop
Pr.261 Power failure stop
selectionpage 362
Pr.502 Stop mode selection at communication error Instruction Manual (Communication)
timepage 158
page 170
selectionpage 128
385
15. (G) Control Parameters
15.7 Stop selection