 Motor settings (200/400 V class)
• Refer to the following list and set the parameters according to the applied motor.
Pr.71
Pr.450
0 (Pr.71 initial value) Standard motor (such as SF-JR)
Constant-torque motor (such as SF-
10
JRCA)
Mitsubishi Electric standard efficiency
20
motor (SF-JR 4P 1.5 kW or lower)
Mitsubishi Electric high-efficiency
40
motor SF-HR
Mitsubishi Electric constant-torque
50
motor SF-HRCA
Mitsubishi Electric high-performance
70
energy-saving motor SF-PR
8090
IPM motor
9090
SPM motor
3
Standard motor (such as SF-JR)
Constant-torque motor (such as SF-
13
JRCA)
Mitsubishi Electric standard efficiency
23
motor (SF-JR 4P 1.5 kW or lower)
Mitsubishi Electric high-efficiency
43
motor SF-HR
Mitsubishi Electric constant-torque
53
motor SF-HRCA
Mitsubishi Electric high-performance
73
energy-saving motor SF-PR
8093
IPM motor
9093
SPM motor
5
Standard motor
15
Constant-torque motor
6
Standard motor
16
Constant-torque motor
9999
(initial
No second applied motor
value)
NOTE
• Regardless of the Pr.71 (Pr.450) setting, offline auto tuning can be performed according to Pr.96 (Pr.463) Auto tuning
setting/status. (Refer to
Motor constant value range when performing
Motor
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Pr.90 (Pr.458), Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
Pr.92 (Pr.460), Pr.93 (Pr.461) (Induction motor)
• 0 to 6000 mH, 9999 (0.1 mH)
Pr.92 (Pr.460), Pr.93 (Pr.461) (PM motor)
• 0 to 650 mH, 9999 (0.01 mH)
Pr.94 (Pr.462)
• 0% to 100%, 9999 (0.1%)
Pr.706 (Pr.738)
• 0 to 5000 mV (rad/s), 9999 (0.1 mV/(rad/s))
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90 (Pr.458),
Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93 (Pr.461),
Pr.94 (Pr.462), Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
Wye
connection
Delta
connection
page 299
for offline auto tuning.)
offline auto tuning (increment)
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Pr.90 (Pr.458), Pr.91 (Pr.459),
Pr.92 (Pr.460) and Pr.93 (Pr.461)
• 0 to 50 Ω, 9999 (0.001 Ω)
Pr.94 (Pr.462)
• 0 to 500 Ω, 9999 (0.01 Ω)
13. (C) Motor Constant Parameters
11
Electronic thermal O/L
relay function
12
Constant-
Standard
torque
13
14
15
16
17
18
19
20