Mitsubishi Electric 800 Series Instruction Manual page 31

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Simple mode parameters (standard model)
Pr.
Pr.
group
0
G000
Torque boost
Maximum
1
H400
frequency
Minimum
2
H401
frequency
3
G001
Base frequency
Multi-speed
4
D301
setting (high
speed)
Multi-speed
5
D302
setting (middle
speed)
Multi-speed
6
D303
setting (low speed)
7
F010
Acceleration time
8
F011
Deceleration time
H000
Electronic thermal
9
C103
O/L relay
Operation mode
79
D000
selection
Terminal 2
125
T022
frequency setting
gain frequency
Terminal 4
126
T042
frequency setting
gain frequency
User group read
160
E440
selection
PM parameter
998
E430
initialization
Automatic
999
E431
parameter setting
*1
Initial value for the FR-E820-0050(0.75K) or lower and FR-E840-0026(0.75K) or lower.
*2
Initial value for the FR-E860-0017(0.75K).
*3
Initial value for the FR-E820-0080(1.5K) to FR-E820-0175(3.7K) and FR-E840-0040(1.5K) to FR-E840-0095(3.7K).
*4
Initial value for the FR-E820-0240(5.5K), FR-E820-0330(7.5K), FR-E840-0120(5.5K), FR-E840-0170(7.5K), FR-E860-0027(1.5K), and FR-E860-
0040(2.2K).
*5
Initial value for the FR-E860-0061(3.7K) to FR-E860-0120(7.5K).
*6
Initial value for the FR-E820-0175(3.7K) or lower, FR-E840-0095(3.7K) or lower, and FR-E860-0061(3.7K) or lower.
*7
Initial value for the FR-E820-0240(5.5K) or higher, FR-E840-0120(5.5K) or higher, FR-E860-0090(5.5K) or higher.
*8
The initial value for the FR-E820-0050(0.75K) or lower, the FR-E840-0026(0.75K) or lower, and the FR-E860-0017(0.75K) is set to the 85% of
the inverter rated current.
*9
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
30
2. Basic Operation
2.4 Frequently-used parameters (simple mode parameters)
Initial value
Name
Increment
Gr.1
6%
5%
0.1%
4%
3%
2%
0.01 Hz
120 Hz
0.01 Hz
0 Hz
0.01 Hz
60 Hz
0.01 Hz
60 Hz
0.01 Hz
30 Hz
0.01 Hz
10 Hz
5 s
0.1 s
10 s
5 s
0.1 s
10 s
Inverter rated
0.01 A
current
1
0
0.01 Hz
60 Hz
0.01 Hz
60 Hz
1
0
1
0
1
9999
*9
Range
Gr.2
*1
*2
*3
0% to 30%
*4
*5
0 to 120 Hz
0 to 120 Hz
50 Hz
0 to 590 Hz
50 Hz
0 to 590 Hz
0 to 590 Hz
0 to 590 Hz
*6
0 to 3600 s
*7
*6
0 to 3600 s
*7
0 to 500 A
*8
0 to 4, 6, 7
50 Hz
0 to 590 Hz
50 Hz
0 to 590 Hz
0, 1, 9999
0, 8009,
8109, 9009,
9109
10, 12, 20,
21, 9999
page
82.)
Application
Set this parameter to obtain a higher starting
torque under V/F control. Also set this when a
loaded motor cannot be driven, the warning
"OL" occurs, and the inverter output is shut off
with the fault indication "E.OC1".
Set the upper limit for the output frequency.
Set the lower limit for the output frequency.
Set this parameter when the rated motor
frequency is 50 Hz. Check the rating plate of
the motor.
Pre-set the speeds that will be switched
among by terminals.
Set the acceleration time.
Set the deceleration time.
Protects the motor from heat. Set the rated
motor current.
Select the start and frequency command
sources.
Change the frequency at the maximum
potentiometer setting (5 V in the initial
setting).
Change the frequency at the maximum
current input (20 mA in the initial setting).
This function restricts the parameters that are
read by the operation panel and parameter
unit.
Select the PM sensorless vector control and
set the parameters that are required to drive a
PM motor.
Changes parameter settings as a batch. The
target parameters include communication
parameters for the Mitsubishi Electric human
machine interface (GOT) connection and the
parameters for the rated frequency settings of
50/60 Hz.
Refer
to
page
374
211
376
34,
39,
195
158
198
174
41,
273
43,
273
143
90
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents