Mitsubishi Electric 800 Series Instruction Manual page 231

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Monitor item
PLC function user
monitor 1
PLC function user
monitor 2
PLC function user
monitor 3
Station number (PU)
Station number (CC-
Link)
Power saving effect
Cumulative energy
saving
PID set point
PID measured value
PID deviation
Input terminal status
Output terminal status —
Option input terminal
*8
status
Option output terminal
*8
status
Option input terminal
status 1 (for
*8
communication)
Option input terminal
status 2 (for
*8
communication)
Option output terminal
status (for
*8
communication)
Motor thermal load
factor
Inverter thermal load
factor
PID measured value 2 0.1%
230
11. (M) Item and Output Signal for Monitoring
11.2 Monitor item selection on operation panel or via communication
Communication
Increment
Pr.
Monitor
and unit
setting
code 1
40
H28
Increment
41
H29
set in the
register
SD1215
42
H2A
1
44
H2C
1
45
H2D
Increment
50
H32
and unit vary
depending
on the
51
H33
parameter
settings.
0.1%
52
H34
0.1%
53
H35
0.1%
54
H36
*9
H0F
55
*10
H10
56
57
*11
H3A
*12
H3B
*13
H3C
0.1%
61
H3D
0.1%
62
H3E
67
H43
Negative
indication
Monitor
*3
*1
*2
(-)
code 2
The user-designated monitor item is displayed using
40240
the PLC function.
Each value of the following special registers is
40241
displayed.
SD1216: displayed with the setting value "40",
SD1217: displayed with the setting value "41",
40242
SD1218: displayed with the setting value "42"
(Refer to the PLC Function Programming Manual.)
The station number of the inverter enabling
40244
communication via the PU connector is displayed.
(Available only for the standard model.)
The station number of the inverter enabling CC-Link
40245
communication is displayed. ("0" is displayed when the
FR-A8NC is not installed.)
40250
The energy saving effect monitoring is enabled. The
item to monitor is selectable from among the saved
power, the average energy saving, and the energy cost
savings. Some of them can be displayed as a
40251
percentage according to the parameter settings. (Refer
to
page
40252
The set point, measured value, and deviation during
40253
PID control operation is displayed. (Refer to
40254
The ON/OFF state of the input terminals on the inverter
*9
is displayed. (Refer to
40215
on the operation panel.)
The ON/OFF state of the output terminals on the
*10
inverter is displayed. (Refer to
40216
indication on the operation panel.)
The ON/OFF state of the input terminals on the digital
input option (FR-A8AX) is displayed on the operation
panel. (Refer to
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
A8AR) is displayed on the operation panel. (Refer to
page 233
The ON/OFF state of the input terminals X0 to X15 on
*11
the digital input option (FR-A8AX) is monitored via
40258
communication.
The ON/OFF state of the input terminal DY on the digital
*12
input option (FR-A8AX) is monitored via
40259
communication.
The ON/OFF state of the output terminals on the digital
*13
output option (FR-A8AY) or the relay output option (FR-
40260
A8AR) is monitored via communication.
The accumulated heat value of the motor thermal O/L
relay is displayed.
40261
The Motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
40262
The Inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
40267
operating conditions are not satisfied. (Refer to
338.)
Description
244.)
page 233
for details of indication
page 233
page 233
for details.)
for details.)
page
338.)
for details of
page

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents