Chapter 2 Ethernet Communication; Outline - Mitsubishi Electric 800 Series Instruction Manual

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2
Ethernet Communication
2.1

Outline

 Precautions for communication
• In order to protect the inverter and the system against unauthorized access by external systems via network, take security
measures that include firewall settings.
• Depending on the network environment, the inverter may not operate as intended due to delays or disconnection in
communication. Carefully consider what type of environment the inverter will be used in and any safety issues related to
its use.
 Ethernet communication specifications
The communication specification varies depending on the specification of the master or the communication protocol.
Item
Category
Data transmission speed
Transmission method
Maximum segment length
Number of cascade connection stages
Topology
Interface
Number of interfaces available
IP version
 Operation status LEDs
LED name
NS
Communication status
MS
Inverter status
Connector for communication
LINK1
(PORT1) status
Connector for communication
LINK2
(PORT2) status
SLMP command request message
NET
reception status
*1
While "1 (initial value)" is set in Pr.1399 Inverter identification enable/disable selection, this LED blinks when the MAC/IP address of the
inverter match to the MAC/IP address specified by using engineering software such as FR Configurator2.
10
2. Ethernet Communication
2.1 Outline
100BASE-TX/10BASE-T
100 Mbps (100BASE-TX) / 10 Mbps (10BASE-T)
Baseband
100 m between the hub and the inverter
Up to 2 (100BASE-TX) / up to 4 (10BASE-T)
Line, start, or a combination of line and star
RJ-45
2
IPv4
Description
LED status
OFF
Red
OFF
Green
Red
OFF
Blinking green
Solid green
OFF
Blinking green
Solid green
OFF
Blinking green
Solid green
Description
Remarks
Duplicate IP address not detected
Duplicate IP address detected
Power-OFF / inverter reset
Operating properly
Fault detected
Power-OFF/link-down
Link-up (Data reception in progress)
Link-up
Power-OFF/link-down
Link-up (Data reception in progress)
Link-up
Power-OFF / inverter identification disabled /
inverter identification paused
Inverter identification in progress
Network operation mode
*1

Advertisement