Mitsubishi Electric 800 Series Instruction Manual page 55

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Description
Operation mode does not switch to the
Network operation mode.
Inverter does not start in the Network
operation mode.
54
2. Ethernet Communication
2.6 CC-Link IE Field Network Basic
Check that the Ethernet cable is installed correctly. (Check for contact fault, break in the cable, etc.)
Check that the inverter is in the External operation mode.
Check that the operation mode switching program is running.
Check that the operation mode switching program has been written correctly.
Check that the inverter starting program is running.
Check that the inverter starting program has been written correctly.
Check that Pr.338 Communication operation command source is not set to External.
Point to be checked