Mitsubishi Electric 800 Series Instruction Manual page 67

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Parameter
Pr.
Register
41000 to
0 to 999
41999
C2 (902)
41902
42092
C3 (902)
43902
125 (903)
41903
42093
C4 (903)
43903
C5 (904)
41904
42094
C6 (904)
43904
126 (905)
41905
42095
C7 (905)
43905
C38 (932)
41932
42122
C39 (932)
43932
C40 (933)
41933
42123
C41 (933)
43933
C42 (934)
41934
42124
C43 (934)
43934
C44 (935)
41935
42125
C45 (935)
43935
1000 to
45000 to
1999
45999
66
2. Ethernet Communication
2.7 MODBUS/TCP
Name
For details on parameter names,
refer to the parameter list in the FR-
E800 Instruction Manual
(Function).
Terminal 2 frequency setting bias
(frequency)
Terminal 2 frequency setting bias
(analog value)
Terminal 2 frequency setting bias
(terminal analog value)
Terminal 2 frequency setting gain
(frequency)
Terminal 2 frequency setting gain
(analog value)
Terminal 2 frequency setting gain
(terminal analog value)
Terminal 4 frequency setting bias
(frequency)
Terminal 4 frequency setting bias
(analog value)
Terminal 4 frequency setting bias
(terminal analog value)
Terminal 4 frequency setting gain
(frequency)
Terminal 4 frequency setting gain
(analog value)
Terminal 4 frequency setting gain
(terminal analog value)
Terminal 4 bias command (torque/
magnetic flux)
Terminal 4 bias (torque/magnetic
flux)
Terminal 4 bias (torque/magnetic
flux) (terminal analog value)
Terminal 4 gain command (torque/
magnetic flux)
Terminal 4 gain (torque/magnetic
flux)
Terminal 4 gain (torque/magnetic
flux) (terminal analog value)
PID display bias coefficient
PID display bias analog value
PID display bias analog value
(terminal analog value)
PID display gain coefficient
PID display gain analog value
PID display gain analog value
(terminal analog value)
For details on parameter names,
refer to the parameter list in the FR-
E800 Instruction Manual
(Function).
Read/write
Read/write
The parameter number + +41000 is the register number.
Read/write
Read/write
Analog value (%) set in C3 (902)
Analog value (%) of the voltage (current) applied to terminal
Read
2
Read/write
Read/write
Analog value (%) set in C4 (903)
Analog value (%) of the voltage (current) applied to terminal
Read
2
Read/write
Read/write
Analog value (%) set in C6 (904)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
Read/write
Analog value (%) set in C7 (905)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
Read/write
Analog value (%) set in C39 (932)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
Read/write
Analog value (%) set in C41 (933)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
Read/write
Analog value (%) set in C43 (934)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
Read/write
Analog value (%) set in C45 (935)
Analog value (%) of the current (voltage) applied to terminal
Read
4
Read/write
The parameter number + 44000 is the register number.
Remarks