Mitsubishi Electric 800 Series Instruction Manual page 38

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Name
1449
Ethernet command source
*1
selection IP address 1
N670
1450
Ethernet command source
*1
selection IP address 2
N671
1451
Ethernet command source
*1
selection IP address 3
N672
1452
Ethernet command source
*1
selection IP address 4
N673
Ethernet command source
1453
selection IP address 3
*1
N674
range specification
Ethernet command source
1454
selection IP address 4
*1
N675
range specification
*1
The setting is applied after an inverter reset or next power-ON.
*2
The setting is available for the FR-E800-EPA.
*3
The setting is available for the FR-E800-EPB.
NOTE
• The monitor items and parameter settings can be read during communication with the Pr.1432 Ethernet communication
check time interval = "0 (initial value)" setting, but such operation will become faulty once the operation mode is changed to
the NET operation mode. When the NET operation mode is selected as the start-up operation mode, communication is
performed once, then an Ethernet communication fault (E.EHR) occurs.
To perform operation or parameter writing via communication, set Pr.1432 to "9999" or a value larger than the communication
cycle or retry time setting. (Refer to
• When the CC-Link IE Field Network Basic is used, a communication error (E.EHR) occurs regardless of the Pr.1432 Ethernet
communication check time interval setting in the following cases: the data addressed to the own station is not received for
the predetermined timeout period or longer, or the status bit of the cyclic transmission addressed to the own station turns OFF
(when the master inverter gives a command to stop the cyclic transmission). (For the details of the timeout period, status bit
of the cyclic transmission, and command to stop the cyclic transmission, refer to the User's Manual of the master device which
supports the CC-Link IE Field Network Basic.)
 Ethernet function selection (Pr.1427 to Pr.1430)
To select the CC-Link IE Field Network Basic for the application, set "61450" in any parameter from Pr.1427 to Pr.1430
Ethernet function selection 1 to 4.
NOTE
• Change the setting if selected communication protocols cannot be used together. (Refer to
 Ethernet IP address for command source selection (Pr.1449 to Pr.1454)
• To limit the network devices that send the operation or speed command through the Ethernet network, set the range of IP
addresses of the devices.
• When Pr.1449 to Pr.1452 = "0 (initial value)", no IP address is specified for command source selection via Ethernet. In this
case, operation commands cannot be sent via Ethernet.
Initial
Setting range
value
0
0
0 to 255
0
0
9999
0 to 255, 9999
9999
page
38.)
Description
To limit the network devices that send the operation or speed
command through the Ethernet network, set the range of IP
addresses of the devices.
When Pr.1449 to Pr.1452 = "0 (initial value)", no IP address is
specified for command source selection via Ethernet. In this
case, operation commands cannot be sent via Ethernet.
page 5
2.6 CC-Link IE Field Network Basic
and
page
122.)
37
2. Ethernet Communication
1
2
3
4
5
6
7
8
9
10