Mitsubishi Electric 800 Series Instruction Manual page 41

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• The Pr.541 Frequency command sign selection setting is applied to the frequency command from RWw1. (Refer to
page
46.)
Rotations per minute
(machine speed) setting
using Pr.37 and Pr.53
Disabled
Enabled
• Relationship between the start command and sign (Pr.541 = "1")
Start
Sign of the frequency
command
+
Forward
rotation
-
+
Reverse
rotation
-
NOTE
• When Pr.541 = "1" (with sign)
• When EEPROM write is specified by turning ON of RYE, write mode error (error code H01) will occur.
• When both RYD and RYE are turned ON while both of them are enabled (Pr.544 ≠ "0"), RYD has precedence.
• When power is turned ON (inverter reset), the initial setting status of the sign bit is "positive" and the set frequency is 0 Hz.
(The motor does not operate at the frequency set before turning OFF the power (inverter reset).)
• When set frequency is written with the instruction code of HED or HEE, the sign of the frequency command is not changed.
 I/O signal list
 When Pr.544 = "0" (compatible with CC-Link Ver.1)
• Remote I/O signals
*7
Device No.
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
RYn5
JOG operation command 2
RYn6
Second function selection
RYn7
Current input selection
RYn8
Pr.185 assignment function (NET X1)
RYn9
Output stop (terminal MRS function)
RYnA
Pr.186 assignment function (NET X2)
RYnB
Pr.184 assignment function (RES)
RYnC
Monitor command
RYnD
Frequency setting command (RAM)
Frequency setting command (RAM,
RYnE
EEPROM)
RYnF
Instruction code execution request
RY(n+1)0 to
Reserved
RY(n+1)7
40
2. Ethernet Communication
2.6 CC-Link IE Field Network Basic
Pr.541
Sign
setting
0
Without 0 to 59000
1
With
-32768 to 32767 (two's complement)
0
Without 0 to 65535
1
With
-32768 to 32767 (two's complement)
Actual operation
command
command
Forward rotation
Reverse rotation
Reverse rotation
Forward rotation
Signal
*2
*2
*1
*1
*1
*2
*2
*2
*1
*5
Setting range
Refer to
Device No.
page
44
RXn0
44
RXn1
44
RXn2
44
RXn3
44
RXn4
44
RXn5
44
RXn6
44
RXn7
*5
44
RXn8
44
RXn9
*5
44
RXnA
44
RXnB
44
RXnC
44
RXnD
44
RXnE
44
RXnF
RX(n+1)0 to
RX(n+1)5
RX(n+1)6
RX(n+1)7
Actual frequency command
0 to 590.00 Hz
-327.68 to 327.67 Hz
It depends on Pr.37 and Pr.53 settings (in 1
increments).
*7
Signal
Forward running
Reverse running
Running (terminal RUN function)
*2
Up to frequency
*2
Overload warning
Pr.193 assignment function (NET Y1)
Frequency detection (terminal FU
*3
function)
Fault (terminal ABC function)
Pr.194 assignment function (NET Y2)
Pr.313 assignment function (DO0)
Pr.314 assignment function (DO1)
Pr.315 assignment function (DO2)
Monitoring
Frequency setting completion (RAM)
Frequency setting completion (RAM,
EEPROM)
Instruction code execution completed
Reserved
Pr.195 assignment function (NET Y3)
Pr.196 assignment function (NET Y4)
Refer to
page
45
45
*3
45
45
45
*6
45
45
*3
45
*6
45
*4
45
*4
45
*4
45
45
45
45
45
*6
45
*6
45