Mitsubishi Electric 800 Series Instruction Manual page 152

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Mode
PU
JOG
NET
PU + EXT
*1
Writing is available depending on the Pr.79 and Pr.340 settings. For details, refer to the FR-E800 Instruction Manual (Function).
Restrictions in each operation mode conform with the computer link specification.
• Real time monitor
Refer to the FR-E800 Instruction Manual (Function) for the register numbers and monitor items of the real time monitor.
• Parameters
Pr.
Register
For details on parameter names,
41000 to
refer to the parameter list in the FR-
0 to 999
41999
E800 Instruction Manual
(Function).
Terminal 2 frequency setting bias
C2 (902)
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
C3 (902)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
125 (903)
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
C4 (903)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
C5 (904)
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
C6 (904)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
126 (905)
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
C7 (905)
Terminal 4 frequency setting gain
43905
(terminal analog value)
Terminal 4 bias command (torque/
C38 (932)
41932
magnetic flux)
Terminal 4 bias (torque/magnetic
42122
flux)
C39 (932)
Terminal 4 bias (torque/magnetic
43932
flux) (terminal analog value)
Terminal 4 gain command (torque/
C40 (933)
41933
magnetic flux)
Terminal 4 gain (torque/magnetic
42123
flux)
C41 (933)
Terminal 4 gain (torque/magnetic
43933
flux) (terminal analog value)
C42 (934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43 (934)
PID display bias analog value
43934
(terminal analog value)
C44 (935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45 (935)
PID display gain analog value
43935
(terminal analog value)
For details on parameter names,
1000 to
45000 to
refer to the parameter list in the FR-
1999
45999
E800 Instruction Manual
(Function).
Read value
H0003
H0004
H0005
Name
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Write value
H0014
Remarks
The parameter number + +41000 is the register number.
Analog value (%) set in C3 (902)
Analog value (%) of the voltage (current) applied to terminal
2
Analog value (%) set in C4 (903)
Analog value (%) of the voltage (current) applied to terminal
2
Analog value (%) set in C6 (904)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C7 (905)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C39 (932)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C41 (933)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C43 (934)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C45 (935)
Analog value (%) of the current (voltage) applied to terminal
4
The parameter number + 44000 is the register number.
151
3. RS-485 Communication
3.5 MODBUS RTU
1
2
3
4
5
6
7
8
9
10