Mitsubishi Electric 800 Series Instruction Manual page 75

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Supported BACnet object
• ANALOG INPUT
Object identifier
1
2
*1
R: Read only, W: Read/Write (Commandable values not supported), C: Read/Write (Commandable values supported)
• ANALOG VALUE
Object identifier
1
2
3
6
8
14
17
20
23
25
52
54
67
200
201
202
203
300
74
2. Ethernet Communication
2.8 BACnet/IP
Present value
Object name
access type
Terminal 2
R
Terminal 4
R
Present value
Object name
access type
Output frequency
R
Output current
R
Output voltage
R
Running speed
R
Converter output
R
voltage
Output power
R
Load meter
R
Cumulative
R
energization time
Actual operation time R
Cumulative power
R
PID set point
R
PID deviation
R
PID measured value2 R
Alarm history 1
R
Alarm history 2
R
Alarm history 3
R
Alarm history 4
R
*2
C
Speed scale
Description
*1
Represents actual input voltage (or input current) of
terminal 2.
(The range varies depending on the Pr.73 and Pr.267
settings.
0 to 10 V (0% to 100%),
0 to 5 V (0% to 100%),
0 to 20 mA (0% to100%))
Represents actual input voltage of terminal 4.
(The range varies depending on the Pr.73 and Pr.267
settings.
2 to 10 V (0% to 100%),
1 to 5 V (0% to 100%),
4 to 20 mA (0% to 100%))
Description
*1
Represents the output frequency value.
Represents the output current value.
Represents the output voltage value.
Represents the running speed value.
Represents the converter output voltage value.
Represents the output power value.
Represents the load meter value.
Represents the cumulative energization time value.
Represents the actual operation time value.
Represents the cumulative power value.
Represents the PID set point.
Represents the PID deviation.
(Minus display is available with reference to 0%, in
0.1% increment.)
Represents the PID measurement 2.
Represents the fault history 1 (the latest fault) monitor.
Represents the fault history 2 (second fault in past)
monitor.
Represents the fault history 3 (third fault in past)
monitor.
Represents the fault history 4 (fourth fault in past)
monitor.
Controls the ratio of the frequency command. (Setting
range: 0.00 to 100.00) (Refer to
Unit
percent
(98)
percent
(98)
Unit
hertz
(27)
amperes
(3)
volts
(5)
revolution-
per-minute
(104)
volts
(5)
kilowatts
(48)
percent
(98)
hours
(71)
hours
(71)
kilowatt-
hours
(19)
no-units
(95)
no-units
(95)
no-units
(95)
no-units
(95)
no-units
(95)
no-units
(95)
no-units
(95)
percent
page
71.)
(98)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents