Mitsubishi Electric 800 Series Instruction Manual page 20

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.
Select [Application Settings] in the "Setting Item List" window.
6.
Set "100 Mbps" for [Communication Speed].
Communication speed setting of the master: 1 Gbps
1.
Select [Basic Settings] in the "Setting Item List" window.
2.
In the "Setting Item" window, go to [Network Configuration Settings] then click
3.
In the "CC-Link IE TSN Configuration" window, set "Low-Speed" for [Communication Period Setting].
 Checking communication
The following table shows the status of the LEDs when communication is established between the programmable controller
and the inverter.
NS
Solid green
Solid green
*1
The LED on either LINK1 or LINK2 will blink depending on the port (port 1 or 2) the Ethernet cable is connected to.
MS
LINK1
*1
Blinking green
next to the [Detailed Setting] field.
LINK2
19
2. Ethernet Communication
2.5 CC-Link IE TSN
1
2
3
4
5
6
7
8
9
10