Mitsubishi Electric 800 Series Instruction Manual page 23

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

*7
Device No.
RYn7
Current input selection
RYn8
Pr.185 assignment function (NET X1)
RYn9
Output stop (terminal MRS function)
RYnA
Pr.186 assignment function (NET X2)
RYnB
Pr.184 assignment function (RES)
RYnC
Monitor command
RYnD
Frequency setting command (RAM)
Frequency setting command (RAM,
RYnE
EEPROM)
RYnF
Instruction code execution request
RY(n+1)0 to
Reserved
RY(n+1)7
Not used (initial data process
RY(n+1)8
completion flag)
Not used (initial data process request
RY(n+1)9
flag)
RY(n+1)A
Error reset request flag
RY(n+1)B
Pr.187 assignment function (NET X3)
RY(n+1)C
Pr.188 assignment function (NET X4)
RY(n+1)D
Pr.189 assignment function (NET X5)
RY(n+1)E
Reserved
RY(n+1)F
*1
These signals are set in the initial setting. Using Pr.180 to Pr.183, input signals assigned to the device numbers can be changed.
For details of Pr.180 to Pr.183, refer to the FR-E800 Instruction Manual (Function).
*2
The signals are fixed. They cannot be changed using parameters.
*3
These signals are set in the initial setting. Using Pr.190 to Pr.192, output signals assigned to the device numbers can be changed.
For details of Pr.190 to Pr.192, refer to the FR-E800 Instruction Manual (Function).
*4
Output signals can be assigned using Pr.313 to Pr.315.
For details, refer to the description of Pr.190 to Pr.196 (Output terminal function selection) in the FR-E800 Instruction Manual (Function).
*5
Input signals can be assigned using Pr.184 to Pr.189.
For details, refer to the description of Pr.184 to Pr.189 (Input terminal function selection) in the FR-E800 Instruction Manual (Function).
*6
Output signals can be assigned using Pr.193 to Pr.196.
For details, refer to the description of Pr.193 to Pr.196 (Output terminal function selection) in the FR-E800 Instruction Manual (Function).
*7
"n" indicates a value determined by the station number.
• Remote registers
*4
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
Data to be written
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
RWwn+8
Fault history No.
RWwn+9
PID set point (0.01% increments)
RWwn+A
PID measured value (0.01%
increments)
RWwn+B
PID deviation (0.01% increments)
RWwn+C
Torque command or torque limit
22
2. Ethernet Communication
2.5 CC-Link IE TSN
Signal
*2
*5
*1
*5
*5
*5
*5
*5
Description
Lower 8 bits
Monitor code 1
*2
Instruction code
H00
*1
*1
*1
Refer to
*7
Device No.
page
23
RXn7
23
RXn8
23
RXn9
23
RXnA
24
RXnB
24
RXnC
24
RXnD
24
RXnE
24
RXnF
RX(n+1)0 to
RX(n+1)5
RX(n+1)6
RX(n+1)7
RX(n+1)8
RX(n+1)9
24
RX(n+1)A
24
RX(n+1)B
24
24
RX(n+1)C to
RX(n+1)F
Refer to
*4
Address
page
25
RWrn
25
RWrn+1
25
RWrn+2
25
RWrn+3
25
RWrn+4
25
RWrn+5
25
RWrn+6
25
RWrn+7
RWrn+8
25
RWrn+9
25
RWrn+A
25
25
RWrn+B
26,
31
RWrn+C
Signal
*3
Fault (terminal ABC function)
Pr.194 assignment function (NET Y2)
Pr.313 assignment function (DO0)
Pr.314 assignment function (DO1)
Pr.315 assignment function (DO2)
Monitoring
Frequency setting completion (RAM)
Frequency setting completion (RAM,
EEPROM)
Instruction code execution completed
Reserved
Pr.195 assignment function (NET Y3)
Pr.196 assignment function (NET Y4)
Not used (initial data process request
flag)
Not used (initial data process
completion flag)
Error status flag
Remote station ready
Reserved
Description
Upper 8 bits
Lower 8 bits
*3
First monitor value
*3
Second monitor value
Reply code 2
Reply code 1
Data to be read
*3
Third monitor value
*3
Fourth monitor value
*3
Fifth monitor value
*3
Sixth monitor value
Fault history No.
Fault record (fault
data)
Fault record (output frequency)
Fault record (output current)
Fault record (output voltage)
Fault record (energization time)
Refer to
page
24
*6
24
*4
24
*4
24
*4
24
24
25
25
25
*6
25
*6
25
25
25
Refer to
page
26
26
26
26
26
26
26
26
26
26
26
26
26