1.1

Product checking

 Inverter model
FR-E8 0-
A
Rating plate
Inverter model
Input rating
Output rating
SERIAL
Country of origin
• A: The voltage class is shown.
Symbol
2
200 V class
4
400 V class
6
575 V class
• B: The inverter rated capacity or the inverter rated current is shown.
Symbol
0.1K to 7.5K
Inverter ND rated capacity (kW)
0008 to 0170
Inverter ND rated current (A)
• C: The communication type and the functional safety specification are shown.
Symbol
Communication / functional safety
None
RS-485 + SIL2/PLd
E
Ethernet + SIL2/PLd
• D: The output specification for monitoring and the rated frequency are shown for the RS-485 model, and the
communication protocol group is shown for the Ethernet model.
Symbol
-1
Pulse (terminal FM), 60 Hz
-4
Voltage (terminal AM), 50 Hz
-5
Voltage (terminal AM), 60 Hz
PA
Protocol group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS/TCP, EtherNet/IP, and BACnet/IP)
PB
Protocol group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS/TCP, PROFINET)
6
1. Introduction
1.1 Product checking
B
C
D
MODEL :FR-E820-0008EPA
INPUT :XXXXX
OUTPUT:XXXXX
SERIAL:XXXXXXXXXXX
MADE IN XXXXX
Voltage class
Description
Monitor output / rated frequency / communication protocol