4.
ACCESSING THE WEB USER
INTERFACE

4.1 Configuring the network settings

The web user interface starts up automatically on power-
up. However, before one can access the Web UI from the
computer connected to the web user interface server, the
network settings must be properly configured from the
setup panel.
Go to the
Main menu > Robot > Network
configure the
DHCP
enabled,
IP
address,
and
Gateway
parameters to match your networking
environment.
DHCP
If you have a DHCP server in your network and you want to
enable a DHCP client function in the Web UI, change the
DHCP enabled
parameter's value to ON. The IP address,
subnet mask, and gateway information will come from
the DHCP server, and you don't need to configure these
parameters. Switching this parameter's value to
you specify the IP settings manually.
When the DHCP client is switched on, it takes some
time for the client to establish a connection to the DHCP
server and retrieve the address information. Usually the
retrieval time is no longer than 60 seconds. During that
time, the old values are displayed for the IP address, subnet
mask, and gateway.
IP address
Specify an IP address for the web user interface server
(DHCP disabled) – for example,
settings, and
address given by the DHCP server (DHCP enabled).
Subnet
mask,
© Kemppi Oy 2020
Subnet mask
Specify a subnet mask for the web user interface server
(DHCP disabled) – for example,
the mask given by the DHCP server (DHCP enabled).
Gateway
OFF
lets
The web user interface does not use a gateway address.
You can leave this parameter as it is (DHCP disabled) or
display the address supplied by the DHCP server (DHCP
enabled).
Configure your computer's network settings accordingly.
Ensure that your computer has an IP address different
from that of the web user interface – for example,
10.0.0.21. Other settings must match each other.
10.0.0.20
– or display the
20
A7 MIG Welder
255.255.255.0
– or display