Pulsecurrent; Pulsebasecurrent; Pulsefrequency; Pulselength - Kemppi A7 350 Integration Manual

Table of Contents

Advertisement

6.1.6 PulseCurrent

This 16-bit function controls the pulse current in the pulse
process.
• The minimum setup value is 99 (99 A).
• The maximum setup value is 800 (800 A).
• The minimum step is 1 (1 A).

6.1.7 PulseBaseCurrent

This 16-bit function controls the base current of the pulse
in the pulse process.
• The minimum setup value is 8 (8 A).
• The maximum setup value is 500 (500 A).
• The minimum step is 1 (1 A).

6.1.8 PulseFrequency

This 16-bit function controls the pulse frequency in the
pulse process.
• The minimum setup value is 10 (1.0 Hz).
• The maximum setup value is 5000 (500.0 Hz).
• The minimum step is 1 (0.1 Hz).

6.1.9 PulseLength

This 16-bit function controls the length of the pulse in the
pulse process.
• The minimum setup value is 15 (150 µs).
• The maximum setup value is 500 (5000 µs).
• The minimum step is 1 (10 µs).
41
© Kemppi Oy 2020

6.1.10 WeldingAllowed

The signal function is used to enable and disable the
StartWelding
signal. When the value is 1 (welding
allowed), the
StartWelding
and stop. When the value is set to 0 (welding disallowed),
the
StartWelding
signal's state to 0 during welding or simulation stops the
operation immediately.
• 0 = Welding disallowed
• 1 = Welding allowed

6.1.11 SimulationMode

This signal function turns the simulation mode on and
off, if the simulation mode is not forced on or off from the
web user interface or from the setup panel. See the
Welder operating manual
In the simulation mode ArcOn, CycleOn, and the other
necessary signals are simulated locally to enable the
welding robot to act as in a normal welding operation.
Welding power remains off and wire is not fed during
simulation. The simulation mode is not allowed during
welding, so changing this signal during welding (or
simulation) has no effect.
• 0 = Simulation mode off. The
function controls a normal welding sequence.
• 1 = Simulation mode on. The
function controls a simulation sequence.
A7 MIG Welder
signal controls welding start
signal has no effect. Changing this
A7 MIG
for more information.
StartWelding
StartWelding
2002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A7 450

Table of Contents