5.1.3 Gas sensor settings

Gas sensor
Set the gas sensor to be
ON
or OFF, on the basis of the gas flow monitoring requirements
of your system.
Gas flow sensing level
Set the gas flow sensing threshold, in liters per minute. When the gas flow exceeds this
level, the system indicates that the gas flow is OK.
Gas type (integrated gas sensor)
Set the type of the shielding gas used in your configuration. This value must be changed
every time the gas type is changed. The gas type selected affects the operation of the gas
flow sensor.
Gas mixture (bus-controlled gas sensor)
Set the gas mixture according to the concentration of the shielding gas used in your
configuration. This value must be changed every time the shielding gas is changed. The
gas mixture affects the function of the gas flow sensor.