3.10 Ethernet (web user interface server)

The welder system is equipped with a web user interface.
The server for the web user interface is in the robot
interface unit, and the connector for the server is at the
rear of the unit.
Connect the web user interface server to a laptop
computer, to another PC, or to a local area network by
using a CAT-5 or CAT-6 shielded Ethernet RJ-45 cable.
The communication speed of the network is 100 Mbps
(100Base-TX) and the maximum length of the cable is 90
m. Both crossover and direct cables are suitable.
The network configuration is described in
"Accessing the web user interface".

3.11 Emergency input functions

There are two emergency input functions in the system,
for the emergency stop and gate door switch.
• The emergency stop function halts the system
when the operator presses an emergency stop
button. After an emergency stop, the system
must be recovered manually.
• The gate door switch halts the system when a
protective gate door is opened. Shielding gas
testing, the torch clean-up function (compressed-
air valve), wire inch, wire retraction, and the touch
sensor can be used in this situation. The touch
sensor voltage is automatically lowered to a
safety level (max. 110 V). After a gate door switch
action, the system is recovered automatically.
Both inputs have a separate three-pin connector at the
rear of the robot interface unit. The connectors have
identical pinout (see
connector
pinout"). The inputs are galvanically isolated
from each other and from the other hardware I/O of the
robot interface unit. The inputs have individual short-
circuit-protected +24 V DC power supplies, each providing
up to 100 mA of continuous current.
Figure 3.14: Emergency input connector pinout
A
Chapter 4,
B
C
A.
Supply out +24 V, 100 mA
B.
Emergency input signal
C.
Supply GND
There are four alternative ways of connecting the
emergency stop and gate door switches
"Connecting the emergency stop
these ways on the basis of your emergency stop circuitry
and the switch types used. Connect the emergency stop
circuitry to the emergency input connector by using
custom cables.
The emergency inputs are configured via software. The
configuration is described in
stop settings. "
© Kemppi Oy 2020
Figure 3.14, "Emergency input
Figure 3.15: Connecting the emergency stop switches
(see Figure 3.15,
switches"). Select one of
Subsection 5.1.7, "Emergency
14
A7 MIG Welder
Opening-action switch on 0
A
V line (default)
B
C
Opening-action switch on
A
+24 V line
B
C
Closing-action switch on 0
A
V line
B
C
Closing-action switch on
A
+24 V line
B
C