Download Print this page

User Interface - Kemppi Mastertig MLS 3003 ACDC Service Manual

Hide thumbs Also See for Mastertig MLS 3003 ACDC:

Advertisement

User interface

Error code
Description
Err 3
Overvoltage
Err 4
Over heating
Err 6
Internal fault, secondary voltage over the limit.
Err 8
Maximum overheat time, machine doesn't cool down fast enough. Only machine
shutdown and restart removes error.
Err 61
Water connection, water cooled gun connected without cooler.
COO Ler
Cooler error:
- Cooling liquid over- / under pressure state
- Overheated alarm
BuS Err
Communication between panel and power source isn't possible
Err rSt
System error, machine makes reset itself.
2.
1.
6.
3.
4.
5.
1.
Gas connector for TIG torch
2.
Welding current connection (negative)
3.
Operation panel
4.
Remote controller connection
5.
TIG -torch control connection
6.
Welding current connection (positive)
7.
Main switch
8.
Gas connector
7
8.
3

Advertisement

loading