3.

HARDWARE INSTALLATION

3.1 Procedures before use

The product is packed in specially designed transport
cartons. Unpack the products from the cartons, and check
that they have not been damaged during transportation.
Check that the contents are complete and nothing is
missing.
The product's packaging material is recyclable.
When moving the welding machine, never pull it by the
welding-gun or other cables. For lifting the power source
and the robot interface unit, use the recesses at both ends of
the robot interface unit.
After installation, make sure all cables and hoses have
enough space to move and are attached properly.
Remember that the cable, plugs, and other electrical
devices may be installed or replaced only by a person
authorized to perform such operations.

3.2 System overview

The welder system supports both gas- and water-cooled
torches. An interconnection cable set without cooling
hoses is available for gas-cooled torches (see
"Connection diagram, gas cooled
torches require a cooling unit and an interconnection
cable set with cooling hoses, both sold separately (see
Figure 3.2, "Connection diagram, water-cooled
© Kemppi Oy 2020
Figure 3.1,
system"). Water-cooled
system").