10.23 HEAT RECOVERY DISABLING SIGNAL DUE TO HIGH CONDENSATION
TEMPERATURE/PRESSURE IN COOLING WORKING MODE
Alarm code
Display in keyboard
Cause of activation
Reset
Reset
Icon
Action
Regulators
Alarm
Reverse valve
Recovery valve
Free-cooling on/off valve
Auxiliary relay
Idle running valve
Supply ventilation
Condensation ventilation
Support/boiler/anti-freeze
Pump/and water evaporator
and condenser
Compressors
Pump down solenoid valve
10.24 UNLOADING SIGNAL DUE TO LOW EVAPORATION PRESSURE IN HEATING WORKING MODE
(Not available)
Display label meaning
Display in keyboard
Cause of activation
Reset
Reset
Icon
Action
Regulators
Alarm
Reverse valve
Recovery valve
Free-cooling on/off valve
Auxiliary relay
Idle running valve
1592025050 iProChill v2.5 10D00 AG v1.3 GB 18.02.2016.docx
b1rC...b4rC (circuit n° 1...4 recovery disabling alarm)
Recovery dis.hi t/p C1...Recovery dis.hi t/p C4
RC01=3, if the probe for disable heat recovery (configured as condensation
temperature or pressure) measures a value >= rC07 set, alarm occur.
The condensation pressure or temperature probe measures a value <=
rc07 set – rC08 differential
Heat recovery disabling function is intervened due to Par. rC09 time
expired.
Automatic
flashing
Alarm relay + buzzer NOT activated
Relay + buzzer NOT activated
It follows its regulation
Off
it follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
It follows its regulation
b1Eu (circuit n° 1 unloading from condenser coil signal)
b2Eu (circuit n° 2 unloading from condenser coil signal)
b3Eu (circuit n° 3 unloading from condenser coil signal)
b4Eu (circuit n° 4 unloading from condenser coil signal)
Unload lo press.circ1...Unload lo press.circ4
When working, if the probe configured as condensation temperature,
configured as pressure control or as evaporation pressure, measures a value <
Un13 set
if the condensation pressure/temperature or the evaporation pressure
measures a value > Un13 + Un14
With unloading function inserted after the time set Par. Un15
Automatic
flashing
Alarm relay + buzzer NOT activated
Relay + buzzer NOT activated
It follows its regulation
it follows its regulation
it follows its regulation
It follows its regulation
It follows its regulation
iProCHILL
187/205