Emerson Dixell iProChill IPC115D Application Manual page 126

Table of Contents

Advertisement

ES 5
Start of working time band 3 (0-24)
ES 6
End of working time band 3 (0-24)
ES 7
Monday energy saving time band
0 = None
1 = Time Band 1
2 = Time Band 2
3 = Time Bands 1 and 2
4 = Time Band 3
5 = Time Bands 1 and 3
6 = Time Bands 2 and 3
7 = All time bands
ES 8
Tuesday energy saving time band
ES 9
Wednesday energy saving time band
ES 10
Thursday energy saving time band
ES 11
Friday energy saving time band
ES 12
Saturday energy saving time band
ES 13
Sunday energy saving time band
ES 14
Increase energy saving setting in chiller mode
ES 15
Energy saving differential in chiller mode
ES 16
Energy saving setting increase in heat pump mode
ES 17
Energy saving differential increase in heat pump mode
ES 18
Monday automatic shutdown time band
ES 19
Tuesday automatic shutdown time band
ES 20
Wednesday automatic shutdown time band
ES 21
Thursday automatic shutdown time band
ES 22
Friday automatic shutdown time band
ES 23
Saturday automatic shutdown time band
ES 24
Sunday automatic shutdown time band
ES 25
Maximum unit working time in OFF from RTC if forced ON via a key
Parameter
Description
AH 1
Auxiliary heating function
0 = Disabled
1 = enabled with control in integration mode
2 = enabled with control in heating mode
AH 2
External air set point auxiliary heating activation
AH 3
External air differential auxiliary heating deactivation
AH 4
Auxiliary heating activation delay time
AH 5
External air set point that deactivates the compressors working in integration
mode
AH 6
External air differential that activates the compressors in integration mode
AH 7
Off compressors delay time in integration mode
AH 8
Thermoregulation selection set
0 = uses the set point (ST04) and the differential (ST08) of the HP
1 = uses the set point and the differential of the auxiliary heating function
2 = add the parameters AH9/AH11 to HP set point (ST04) and use the
differentials AH10/AH12
AH 9
Auxiliary heating set point on / off
AH 10
Band proportional auxiliary heating ON / OFF
AH 11
Auxiliary modulating heating set point
AH 12
Auxiliary modulating heating proportional band
AH 13
Auxiliary heating modulating minimum output value
AH 14
Auxiliary heating modulating maximum output value
AH 15
Auxiliary Output heating minimum maintaining value of to higher temperatures
modulating the set point
0 = Not enabled
1 = Enabled
AH 16
Enable the auxiliary heater in defrost
0 = Not enabled
1 = Enabled
Parameter
Description
1592025050 iProChill v2.5 10D00 AG v1.3 GB 18.02.2016.docx
Auxiliary heating
Compressor
0
24.00
Hr
0
24.00
Hr
0
7
0
7
0
7
0
7
0
7
0
7
0
7
-50.0
110
°C
-58
230
°F
0.1
25.0
°C
1
45
°F
-50.0
110
°C
-58
230
°F
0.1
25.0
°C
1
45
°F
0
7
0
7
0
7
0
7
0
7
0
7
0
7
0
250
Min
min
max
um
Resolution
0
2
-50.0
110
°C
-58
230
°F
0.1
25.0
°C
1
45
°F
0
250
°C
-50.0
110
°F
0.1
25.0
°C
1
45
°F
0
250
0
2
-50.0
110
°C
-58
230
°F
0.1
25.0
°C
1
45
°F
-50.0
110
°C
-58
230
°F
0.1
25.0
°C
1
45
°F
0
AH14
%
AH13
100
%
0
1
0
1
min
max
um
Resolution
iProCHILL
10 Min
10 Min
Dec
int
Dec
int
Dec
int
Dec
int
10 Min
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
126/205