FA19
Proportional regulation
Set temperature / pressure for maximum fan speed in h.p. mode. This
allows you to set the condensation temperature / pressure value in h.p.
mode that corresponds to minimum fan speed.
Step regulation
SET 4th STEP This allows you to set the condensation temperature /
pressure value in heat pump mode that corresponds to the operation of
the relay output in ON configured as the 4th condensation fan speed
step.
FA20
Proportional regulation
Set temperature / pressure for minimum fan speed in h.p. mode. This
allows you to set the condensation temperature / pressure value in h.p.
mode that corresponds to maximum fan speed.
Step regulation
SET 3rd STEP This allows you to set the condensation temperature /
pressure value in heat pump mode that corresponds to the operation of
the relay output in ON configured as the 3rd condensation fan speed
step.
FA21
Proportional regulation
Proportional band regulation of fans in heat pump mode This allows you
to set a temperature / pressure differential that corresponds to a variation
from minimum to maximum fan speed.
Step regulation
With Par. FA01=2/3 becomes the differential on the step itself of circuit 1
in heat pump (see fans regulation graph).
FA22
Proportional regulation
Differential CUT- OFF in heat pump. This allows you to set a temperature
/ pressure differential in h.p. mode to shut off the fan.
Step regulation
With Par. FA01=2/3 becomes the differential on the step itself of circuit 2
in heat pump mode (see fans regulation graph).
FA23
Over ride CUT- OFF in h.p. This allows you to set a temperature /
pressure differential in h.p. mode, where the fan maintains minimum
speed.
FA24
Night function speed in HP mode. This allows you to set a maximum value for
the proportional regulation of the fans in h.p. It is expressed as a
percentage of the maximum voltage allowed.
FA25
Third step setting in chiller mode
SET 3rd STEP This allows you to set the condensation temperature /
pressure value in chiller mode that corresponds to the operation in ON of
the relay output, configured as the 3rd condensation fan speed step.
FA26
Fourth step setting in chiller mode
SET 4th STEP This allows you to set the condensation temperature /
pressure value in chiller mode that corresponds to operation in ON of the
relay output, configured as the 4th condensation fan speed step.
FA27
Differential on circ.3 steps in chiller mode
With Par. FA01=2/3 becomes the differential on the step itself of circuit
3 chiller (see fans regulation graph).
FA28
Differential on circ.4 steps in chiller mode
With Par. FA01=2/3 becomes the differential on the step itself of circuit
4 chiller (see fans regulation graph).
FA29
SET 2nd STEP This allows you to set the condensation temperature /
pressure value in heat pump mode that corresponds to the operation of
the relay output in ON configured as the 2nd condensation fan speed
step.
FA30
SET 1st STEP This allows you to set the condensation temperature /
pressure value in heat pump mode that corresponds to the operation of
the relay output in ON configured as the 1st condensation fan speed
step.
FA31
Differential on circ.3 steps in HP mode
With Par. FA01 = 2 / 3 becomes the differential on the step itself of circuit
3 in heat pump mode (see fans regulation graph).
FA32
Differential on circ.4 steps in HP mode
With Par. FA01 = 2 / 3 becomes the differential on the step itself of circuit
4 heat pump mode (see fans regulation graph).
1592025050 iProChill v2.5 10D00 AG v1.3 GB 18.02.2016.docx
Condensation fan step 3 / 4 in chiller mode
Condensation fan step 3 / 4 in heat pump mode
Operation in defrost (dF33 = 2)
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
FA17
FA18
%
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
-50.0
110
°C
-58
230
°F
0.0
50.0
Bar
0
725
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
0.1
25.0
°C
0
45
°F
0.1
14.0
Bar
1
203
Psi
iProCHILL
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec
int
Dec