NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the
Lifecycle Controller User's Guide at
NOTE:
While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the
system; the new card automatically updates to the same firmware and configuration of the faulty one. For more
information about the Part replacement configuration, see the
www.dell.com/idracmanuals
Before working inside your system
Prerequisites
Follow the safety guidelines listed in
Steps
1. Power off the system and all attached peripherals.
2. Disconnect the system from the electrical outlet, and disconnect the peripherals.
3. If applicable, remove the system from the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals.
4. Remove the system cover.
After working inside your system
Prerequisites
Follow the safety guidelines listed in
Steps
1. Replace the system cover.
2. If applicable, install the system into the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals.
3. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
Recommended tools
You need the following tools to perform the removal and installation procedures:
•
Key to the bezel lock
The key is required only if your system includes a bezel.
•
Phillips #1 screwdriver
•
Phillips #2 screwdriver
•
Torx #T20 screwdriver
•
5mm hex nut screwdriver
•
Plastic scribe
•
1/4 inch flat blade screwdriver
•
Wrist grounding strap connected to the ground
•
ESD mat
You need the following tools to assemble the cables for a DC power supply unit:
•
AMP 90871-1 hand-crimping tool or equivalent
•
Tyco Electronics 58433-3 or equivalent
•
Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
NOTE:
Use alpha wire part number 3080 or equivalent (65/30 stranding).
44
Installing and removing system components
https://www.dell.com/idracmanuals
Safety instructions
on page 43.
Safety instructions
on page 43.
Lifecycle Controller User's Guide at
https://