Image 10-2
10.4 Lighting Mirror: Vertical (y) Adjustment
Turn knob (B) with fingers to adjust mirror vertically until no horizontal band is present in upper or lower edge
of image
Image 10-3
10.5 Focus: Relay tube lens focus adjustment
Adjust NUBs (A&B) until the edges of both bands are visible in the projected image (See above picture A).
•
- Turn stub screw counter clockwise to loosen (1)
•
- Adjust by pushing stub laterally up/down (2) to find the focal point where vertical band achieves the best
focus.
•
- Turn stub screw CW to lock adjustment.
Finalize operation by repeating mirror horizontal adjustment.
Image 10-4
1
2
Image 10-5: Focus adjustment location
Optical adjustments
723–0018 /02
F70